    Design and Control Benchmark of Rib-Stiffened Concrete Slabs Equipped with an Adaptive Tensioning System

    Source: Journal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 001::page 04023200-1
    Author:
    Arka P. Reksowardojo
    ,
    Gennaro Senatore
    ,
    Manfred Bischoff
    ,
    Lucio Blandini
    DOI: 10.1061/JSENDH.STENG-12320
    Publisher: ASCE
    Abstract: Floor systems are typically designed to satisfy tight deflection limits under out-of-plane loading. Although the use of concrete flat slabs is common in the built environment due to the ease of construction, the load-bearing performance is inefficient because the material is not optimally distributed within the cross section to take the bending caused by external loads. This typically results in significant oversizing. Floor slabs account for more than 50% of the material mass and associated emissions embodied in typical low-rise reinforced concrete buildings. In addition, the volume of carbon-intensive cement production has tripled in the last three decades. Therefore, lightweight floor systems that use minimum material resources causing low emissions can have a significant impact on reducing adverse environmental impacts of new constructions. Recent work has shown that rib-stiffened slabs offer significant potential for material savings compared with flat slabs. This work investigates adaptive rib-stiffened slabs equipped with an adaptive tensioning system. The adaptive tensioning system comprises cables embedded within the concrete rib through a duct that enables varying the cable tension as required to counteract the effect of different loading conditions without applying permanent prestress that might cause unwanted long-term effects including tension loss and amplified deflection. The cables are positioned following a profile so that the tension force is applied eccentrically to the neutral axis of the slab-ribs assembly. The resulting system of forces causes a bending moment that counteracts the effect of the external load. The rib placement is optimized through a greedy algorithm with a heuristic based on the direction of the principal stresses. The deflection of the slab is reduced by adjusting the cable tensile forces computed by a quasi-static controller. Benchmark studies comparing different cable profiles and active rib layouts are carried out to determine an efficient control configuration. A case study of an 8×8-m adaptive rib-stiffened slab is implemented to evaluate material savings potential. Results show that the adaptive slab solution can achieve up to 67% of material savings compared with an equivalent passive flat slab.
    • Download: (1.874Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design and Control Benchmark of Rib-Stiffened Concrete Slabs Equipped with an Adaptive Tensioning System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4296750
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorArka P. Reksowardojo
    contributor authorGennaro Senatore
    contributor authorManfred Bischoff
    contributor authorLucio Blandini
    date accessioned2024-04-27T22:28:51Z
    date available2024-04-27T22:28:51Z
    date issued2024/01/01
    identifier other10.1061-JSENDH.STENG-12320.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4296750
    description abstractFloor systems are typically designed to satisfy tight deflection limits under out-of-plane loading. Although the use of concrete flat slabs is common in the built environment due to the ease of construction, the load-bearing performance is inefficient because the material is not optimally distributed within the cross section to take the bending caused by external loads. This typically results in significant oversizing. Floor slabs account for more than 50% of the material mass and associated emissions embodied in typical low-rise reinforced concrete buildings. In addition, the volume of carbon-intensive cement production has tripled in the last three decades. Therefore, lightweight floor systems that use minimum material resources causing low emissions can have a significant impact on reducing adverse environmental impacts of new constructions. Recent work has shown that rib-stiffened slabs offer significant potential for material savings compared with flat slabs. This work investigates adaptive rib-stiffened slabs equipped with an adaptive tensioning system. The adaptive tensioning system comprises cables embedded within the concrete rib through a duct that enables varying the cable tension as required to counteract the effect of different loading conditions without applying permanent prestress that might cause unwanted long-term effects including tension loss and amplified deflection. The cables are positioned following a profile so that the tension force is applied eccentrically to the neutral axis of the slab-ribs assembly. The resulting system of forces causes a bending moment that counteracts the effect of the external load. The rib placement is optimized through a greedy algorithm with a heuristic based on the direction of the principal stresses. The deflection of the slab is reduced by adjusting the cable tensile forces computed by a quasi-static controller. Benchmark studies comparing different cable profiles and active rib layouts are carried out to determine an efficient control configuration. A case study of an 8×8-m adaptive rib-stiffened slab is implemented to evaluate material savings potential. Results show that the adaptive slab solution can achieve up to 67% of material savings compared with an equivalent passive flat slab.
    publisherASCE
    titleDesign and Control Benchmark of Rib-Stiffened Concrete Slabs Equipped with an Adaptive Tensioning System
    typeJournal Article
    journal volume150
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/JSENDH.STENG-12320
    journal fristpage04023200-1
    journal lastpage04023200-19
    page19
    treeJournal of Structural Engineering:;2024:;Volume ( 150 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian