Show simple item record

contributor authorBotros, K.K.
contributor authorChan, N.
contributor authorGeerligs, J.
contributor authorLeong, K.
contributor authorHickey, B.
contributor authorGong, I.
date accessioned2023-11-29T19:03:14Z
date available2023-11-29T19:03:14Z
date copyright10/27/2022 12:00:00 AM
date issued10/27/2022 12:00:00 AM
date issued2022-10-27
identifier issn0195-0738
identifier otherjert_145_1_012801.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4294546
description abstractInline vertical separators are commonly employed in natural gas transmission facilities (e.g., receipt stations) to filter liquid contaminants such as compressor oil, glycol, and free water from the gas stream. Manufacturers of these separators have claimed liquid removal efficiencies of 98–99% for droplet sizes ≥ 8 μm. However, these contaminants have been found invariably in piping systems downstream of these separators, suggesting inadequate separator performance. Currently, there is a lack of ability to verify manufacturer claims due to difficulties in quantifying liquid contaminants and droplet characteristics. The potential consequences of having such contaminants include lower gas quality, impaired gas metering accuracy, corrosion and damage to equipment/instrumentation, and adverse impacts on industrial and residential end users. This paper presents performance testing of a mesh-vane-type vertical separator conducted on high pressure, pipeline quality, natural gas in the range of 4–5 MPa and flow velocity in the range of 1.3–13 m/s in the DN150 separator inlet (hence turndown ratio of 10:1). Four different spray nozzles were used to inject and atomize industrial compressor oil with a liquid-to-gas mass loading ratio of 0.06–1.8%. Test results revealed that the average bulk efficiency separation performance for this separator is approximately 90.34%. This was found to be independent of the liquid-to-gas mass loading ratio. The effective Souders–Brown K-factor was found to be 0.15 m/s. This is below literature published data in the range of 0.27–0.3 m/s for horizontal flow, vane-pack-type separators. Liquid separation tests were also conducted following the injection of solid glass beads. Liquid separation efficiency decreased by approximately 9%, following the injection of 7 kg of industrial glass beads over a period of approximately 4 h. This was attributed to accumulation of solids in the vane pack.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental Investigation into Liquid and Solid Separation by an Industrial Mesh-Vane-Type Separator on Natural Gas at 4–5 MPa, Different Liquid Loadings and Gas Flows
typeJournal Paper
journal volume145
journal issue1
journal titleJournal of Energy Resources Technology
identifier doi10.1115/1.4055907
journal fristpage12801-1
journal lastpage12801-11
page11
treeJournal of Energy Resources Technology:;2022:;volume( 145 ):;issue: 001
contenttypeFulltext