    Evaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. I: Experimental Research

    Source: Journal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 008::page 04022105
    Author:
    Luis Alberto Bedriñana
    ,
    Masanori Tani
    ,
    Susumu Kono
    ,
    Minehiro Nishiyama
    DOI: 10.1061/(ASCE)ST.1943-541X.0003349
    Publisher: ASCE
    Abstract: This paper presents the results of an experimental investigation on the performance of half-scale, unbonded, post-tensioning, precast concrete walls subjected to fully reversed cyclic loads. Moreover, this paper discusses the damage progression and failure mechanism of each specimen, associated with their construction details (damper types and confinement details of the boundary elements). Five isolated walls were tested, each consisting of precast concrete panels joined only by unbonded post-tensioning strands. The bottom joint of the walls featured two kinds of dampers: Three specimens had mild steel reinforcement, crossing the bottom joint, and the other two specimens had external replaceable hysteretic dampers, attached to the wall sides. Different types of confinement details at the boundary elements were used among the specimens. Steel fibers were mixed into the concrete of one specimen. The prestressing load ratio was 0.05 in most of the specimens. An additional axial load of 468.5 kN was applied to each specimen (additional axial load ratio of about 0.04), before any lateral loading. Quasi-static, displacement-controlled loads were applied to the specimens until a significant strength reduction was observed. Although only moderate axial loads were applied, most of the specimens sustained drifts above 3% while maintaining their lateral strength, gravity load stability, and self-centering. A better performance was observed in the specimens with external dampers, with drifts above 4%, less residual drifts and less cover concrete spalling, particularly in the specimen with steel fibers. The external dampers were very effective in dissipating energy before fracture, until 3% drifts. On the other hand, the specimens with internal dampers sustained unexpected damage at their bottom joint, after reaching their peak strength. For instance, the gravity load-carrying capacity of one specimen with internal dampers was compromised after 4% drifts. Then, the use of external replaceable dampers provided higher performance and post-earthquake recovery for unbonded post-tensioned precast walls. Additional design recommendations are provided based on the test results.
    • Download: (2.882Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Evaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. I: Experimental Research

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4286671
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorLuis Alberto Bedriñana
    contributor authorMasanori Tani
    contributor authorSusumu Kono
    contributor authorMinehiro Nishiyama
    date accessioned2022-08-18T12:28:01Z
    date available2022-08-18T12:28:01Z
    date issued2022/06/08
    identifier other%28ASCE%29ST.1943-541X.0003349.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286671
    description abstractThis paper presents the results of an experimental investigation on the performance of half-scale, unbonded, post-tensioning, precast concrete walls subjected to fully reversed cyclic loads. Moreover, this paper discusses the damage progression and failure mechanism of each specimen, associated with their construction details (damper types and confinement details of the boundary elements). Five isolated walls were tested, each consisting of precast concrete panels joined only by unbonded post-tensioning strands. The bottom joint of the walls featured two kinds of dampers: Three specimens had mild steel reinforcement, crossing the bottom joint, and the other two specimens had external replaceable hysteretic dampers, attached to the wall sides. Different types of confinement details at the boundary elements were used among the specimens. Steel fibers were mixed into the concrete of one specimen. The prestressing load ratio was 0.05 in most of the specimens. An additional axial load of 468.5 kN was applied to each specimen (additional axial load ratio of about 0.04), before any lateral loading. Quasi-static, displacement-controlled loads were applied to the specimens until a significant strength reduction was observed. Although only moderate axial loads were applied, most of the specimens sustained drifts above 3% while maintaining their lateral strength, gravity load stability, and self-centering. A better performance was observed in the specimens with external dampers, with drifts above 4%, less residual drifts and less cover concrete spalling, particularly in the specimen with steel fibers. The external dampers were very effective in dissipating energy before fracture, until 3% drifts. On the other hand, the specimens with internal dampers sustained unexpected damage at their bottom joint, after reaching their peak strength. For instance, the gravity load-carrying capacity of one specimen with internal dampers was compromised after 4% drifts. Then, the use of external replaceable dampers provided higher performance and post-earthquake recovery for unbonded post-tensioned precast walls. Additional design recommendations are provided based on the test results.
    publisherASCE
    titleEvaluation of the Seismic Performance of Unbonded Post-Tensioned Precast Concrete Walls with Internal and External Dampers. I: Experimental Research
    typeJournal Article
    journal volume148
    journal issue8
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003349
    journal fristpage04022105
    journal lastpage04022105-24
    page24
    treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian