description abstractConcrete bridges in extremely aggressive environments deteriorate mainly from corrosion of carbon steel prestressing strands and rebars. In prestressed concrete girders, corrosion might occur in the transverse reinforcement, which results in a decrease in shear resistance. Corrosion-free glass fiber reinforced polymer (GFRP) rebars and corrosion-resistant stainless steel rebars are promising solutions to address corrosion. However, GFRP rebars have lower ultimate strain, elastic modulus, and transverse shear capacity than stainless steel rebars. Two full-scale 12.8-m (42-ft) long AASHTO (American Association of State Highway and Transportation Officials) Type II girders with a deck slab on top of them were tested in shear at both ends. One girder was reinforced with duplex stainless steel Grade 520 (75) stirrups, and the other was reinforced with GFRP stirrups. Both girders had 11 carbon steel prestressing strands, each initially stressed to 75% of the strand’s ultimate stress. The girders were composite with a deck slab and had a smooth interface between the girder and slab. The objective was to experimentally assess the structural behavior of the girders. The girder reinforced with stainless steel stirrups failed in flexural shear while the girder reinforced with GFRP stirrups failed in interface shear due to the lower transverse shear capacity of GFRP rebars and smooth interface between the girder and slab. The experimental shear force at the failure of the girder reinforced with stainless steel stirrups was 9.1% greater than that reinforced with GFRP stirrups. Also, the direct replacement of stainless steel confinement reinforcement with GFRP resulted in strand slippage. It was found that the current AASHTO LRFD shear design provisions are conservative in predicting the vertical shear resistance of a girder reinforced with stainless steel stirrups or GFRP stirrups. The research findings will be helpful in the development of design guide specifications for prestressed concrete girders reinforced with GFRP stirrups.
publisherASCE
titleStructural Assessment of AASHTO Type II Prestressed Concrete Girder with GFRP or Stainless-Steel Shear Reinforcement
typeJournal Article
journal volume27
journal issue7
journal titleJournal of Bridge Engineering
identifier doi10.1061/(ASCE)BE.1943-5592.0001899
journal fristpage04022056
journal lastpage04022056-13
page13
treeJournal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record