description abstractThe structural performance of reinforced concrete (RC) beams strengthened in shear with embedded through-section (ETS) glass fiber-reinforced polymer (GFRP) bars is experimentally and analytically investigated. Three-point bending tests are performed. The investigated parameters include the number of existing steel stirrups (ρsw = 0.28%), concrete compressive strength (fc′ = 27 and 43 MPa), shear span-to-effective depth ratio (a/d = 2.4, 3.6, and 4.8), anchorage presence (with and without anchorage), and anchorage properties (steel and GFRP anchorage systems, as well as the anchorage length). The results indicate that the shear capacity and stiffness of the beams are enhanced by applying ETS-GFRP, increasing concrete strength, and decreasing shear span-to-effective depth ratio. The ETS-GFRP-strengthened beams exhibit a more ductile failure mode than the unstrengthened beam owing to concrete crushing in loading areas. The beam stiffness depends significantly on the anchorage presence and properties, and the beam shear capacities differ considerably for different anchorage systems. Anchorage with four steel nuts or two GFRP nuts at the ETS bar ends provides the highest shear resistance and stiffness for the ETS-strengthened beams. The results of this study suggest that the details and configuration of the anchorage system should be carefully considered for the development of unanimous specifications. Additionally, previously proposed shear models can be used to conservatively analyze test results with sufficient accuracy. The newly developed model for estimation of the shear strengths of ETS-GFRP-strengthened beams and the effective strains in ETS-GFRP bars agrees well with the test data.
publisherASCE
titleExperimental and Analytical Study on Shear Performance of Embedded Through-Section GFRP-Strengthened RC Beams
typeJournal Article
journal volume26
journal issue5
journal titleJournal of Composites for Construction
identifier doi10.1061/(ASCE)CC.1943-5614.0001235
journal fristpage04022046
journal lastpage04022046-17
page17
treeJournal of Composites for Construction:;2022:;Volume ( 026 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record