Show simple item record

contributor authorAmbrose, Alexander B.
contributor authorDetelich, Joshua F.
contributor authorWeinmann, Maxwell
contributor authorHammond, Frank L., III
date accessioned2022-05-08T08:28:42Z
date available2022-05-08T08:28:42Z
date copyright2/9/2022 12:00:00 AM
date issued2022
identifier issn1932-6181
identifier othermed_016_01_011004.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4283971
description abstractCritical care patients who experience acute respiratory distress syndrome are commonly placed on mechanical ventilators to improve oxygen delivery and overall gas exchange of the pulmonary system. With the pulmonary inflammation accompanying acute respiratory distress syndrome (ARDS), patients experience significant alterations in ventilation–perfusion (V/Q) ratios resulting in lower blood oxygenation. In severe cases, patients are typically rotated into a prone position to facilitate improved blood flow to portions of the lung that were not previously participating in the gas exchange process. However, proning a patient increases the risk of complications, requires up to seven hospital staff members to carry out, and does not guarantee an improvement in the patient's condition. The low-cost V/Q vest presented here was designed to reproduce the effects of proning while also requiring less hospital staff than the proning process. Additionally, the V/Q Vest helps hospital staff predict whether patients would respond well to a proning treatment. A pilot study was conducted on nine patients with ARDS from coronavirus disease 2019 (COVID-19). The average increase in oxygenation with the V/Q Vest treatment for all patients was 19.7±38.1%. Six of the nine patients responded positively to the V/Q Vest treatment, exhibiting increased oxygenation. The V/Q Vest also helped hospital staff predict that three of the five patients that were proned would experience an increase in oxygenation. An increase in oxygenation resulting from V/Q Vest treatment exceeded that of the proning treatment in two of these five proned patients.
publisherThe American Society of Mechanical Engineers (ASME)
titleEvaluation of a Pneumatic Vest to Treat Symptoms of ARDS Caused by COVID-19
typeJournal Paper
journal volume16
journal issue1
journal titleJournal of Medical Devices
identifier doi10.1115/1.4053387
journal fristpage11004-1
journal lastpage11004-7
page7
treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record