    Seismic Response of Yielding Multistory Steel Buildings Equipped with Pressurized Sand Dampers

    Source: Journal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 007::page 04022071
    Author:
    Gholamreza Moghimi
    ,
    Nicos Makris
    DOI: 10.1061/(ASCE)ST.1943-541X.0003364
    Publisher: ASCE
    Abstract: This paper investigates the seismic response analysis of the 9-story SAC building equipped with pressurized sand dampers, a new type of low-cost energy dissipation device where the material enclosed within the damper housing is pressurized sand. The strength of the pressurized sand damper is proportional to the externally exerted pressure on the sand via prestressed steel rods; therefore, the energy dissipation characteristics of a given pressurized sand damper can be adjusted according to a specific application. The strong pinching behavior of pressurized sand dampers was characterized with a previously developed three-parameter Bouc-Wen hysteretic model that for this study was implemented in the open source code OpenSees with a C++ algorithm, and it was used to analyze the seismic response of the 9-story SAC building subjected to six strong ground motions that exceed the design response spectrum for all soil categories. The paper shows that for the family of strong ground motions used in this study, pressurized sand dampers with strength of the order of 5%–10% of the weights of their corresponding floors were able to keep the interstory drifts of the 9-story SAC building at or below 1%, while base shears and peak plastic hinge rotations were reduced in the damped configuration. Supplemental damping produced mixed results on floor accelerations; nevertheless, in most floors, peak accelerations were reduced.
    • Download: (10.87Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Seismic Response of Yielding Multistory Steel Buildings Equipped with Pressurized Sand Dampers

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282492
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorGholamreza Moghimi
    contributor authorNicos Makris
    date accessioned2022-05-07T20:29:02Z
    date available2022-05-07T20:29:02Z
    date issued2022-04-18
    identifier other(ASCE)ST.1943-541X.0003364.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282492
    description abstractThis paper investigates the seismic response analysis of the 9-story SAC building equipped with pressurized sand dampers, a new type of low-cost energy dissipation device where the material enclosed within the damper housing is pressurized sand. The strength of the pressurized sand damper is proportional to the externally exerted pressure on the sand via prestressed steel rods; therefore, the energy dissipation characteristics of a given pressurized sand damper can be adjusted according to a specific application. The strong pinching behavior of pressurized sand dampers was characterized with a previously developed three-parameter Bouc-Wen hysteretic model that for this study was implemented in the open source code OpenSees with a C++ algorithm, and it was used to analyze the seismic response of the 9-story SAC building subjected to six strong ground motions that exceed the design response spectrum for all soil categories. The paper shows that for the family of strong ground motions used in this study, pressurized sand dampers with strength of the order of 5%–10% of the weights of their corresponding floors were able to keep the interstory drifts of the 9-story SAC building at or below 1%, while base shears and peak plastic hinge rotations were reduced in the damped configuration. Supplemental damping produced mixed results on floor accelerations; nevertheless, in most floors, peak accelerations were reduced.
    publisherASCE
    titleSeismic Response of Yielding Multistory Steel Buildings Equipped with Pressurized Sand Dampers
    typeJournal Paper
    journal volume148
    journal issue7
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003364
    journal fristpage04022071
    journal lastpage04022071-16
    page16
    treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian