    Fatigue Behavior of Rib-to-Floor Beam Junctions with Separate Inner Stiffeners in Orthotropic Steel Bridge Decks

    Source: Journal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 005::page 04022019
    Author:
    Jin Di
    ,
    Jie Wang
    ,
    Xuhong Zhou
    ,
    Xi Peng
    ,
    Fengjiang Qin
    DOI: 10.1061/(ASCE)BE.1943-5592.0001857
    Publisher: ASCE
    Abstract: The fatigue of orthotropic steel bridge decks (OSBDs) is a bottleneck for its application, especially the fatigue of rib-to-floor beam (RF) junction. Thus, it is necessary to optimize the RF junction to improve its fatigue performance. In this study, the effect of equipping a separate inner stiffener (SIS) on the fatigue performance of an RF junction was investigated. The growth of fatigue cracks in the weld toe of the rib at the RF junction tip (RT) was examined through static and fatigue tests of a full-scale OSBD. Moreover, the influence of crack growth on other details was also studied. Subsequently, the fatigue strengths of two cracked details and the minimum fatigue strengths of four uncracked details were evaluated considering the results of a finite-element analysis. Finally, the verified finite-element model was used to analyze the influence of the form and size of the inner stiffener on the fatigue performance of RF junction. The SIS was found to be the most optimal inner stiffener, and its recommended size was obtained. When the recommended RF junction was adopted, the most unfavorable stress of the RT detail most prone to fatigue cracking could be reduced by 51.3%.
    • Download: (3.062Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Fatigue Behavior of Rib-to-Floor Beam Junctions with Separate Inner Stiffeners in Orthotropic Steel Bridge Decks

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282438
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorJin Di
    contributor authorJie Wang
    contributor authorXuhong Zhou
    contributor authorXi Peng
    contributor authorFengjiang Qin
    date accessioned2022-05-07T20:26:44Z
    date available2022-05-07T20:26:44Z
    date issued2022-5-1
    identifier other(ASCE)BE.1943-5592.0001857.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282438
    description abstractThe fatigue of orthotropic steel bridge decks (OSBDs) is a bottleneck for its application, especially the fatigue of rib-to-floor beam (RF) junction. Thus, it is necessary to optimize the RF junction to improve its fatigue performance. In this study, the effect of equipping a separate inner stiffener (SIS) on the fatigue performance of an RF junction was investigated. The growth of fatigue cracks in the weld toe of the rib at the RF junction tip (RT) was examined through static and fatigue tests of a full-scale OSBD. Moreover, the influence of crack growth on other details was also studied. Subsequently, the fatigue strengths of two cracked details and the minimum fatigue strengths of four uncracked details were evaluated considering the results of a finite-element analysis. Finally, the verified finite-element model was used to analyze the influence of the form and size of the inner stiffener on the fatigue performance of RF junction. The SIS was found to be the most optimal inner stiffener, and its recommended size was obtained. When the recommended RF junction was adopted, the most unfavorable stress of the RT detail most prone to fatigue cracking could be reduced by 51.3%.
    publisherASCE
    titleFatigue Behavior of Rib-to-Floor Beam Junctions with Separate Inner Stiffeners in Orthotropic Steel Bridge Decks
    typeJournal Paper
    journal volume27
    journal issue5
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001857
    journal fristpage04022019
    journal lastpage04022019-13
    page13
    treeJournal of Bridge Engineering:;2022:;Volume ( 027 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian