Show simple item record

contributor authorMorgan Broberg
contributor authorSoheil Shafaei
contributor authorEmre Kizilarslan
contributor authorJungil Seo
contributor authorAmit H. Varma
contributor authorMichel Bruneau
contributor authorRon Klemencic
date accessioned2022-05-07T20:26:36Z
date available2022-05-07T20:26:36Z
date issued2022-02-07
identifier other(ASCE)ST.1943-541X.0003296.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282432
description abstractComposite plate shear walls–concrete-filled (C-PSW/CF) are a new and innovative lateral force–resisting system intended for high-rise buildings. High-rise building applications of this system are particularly efficient in the coupled wall configuration, in which the walls are C-PSW/CF and the coupling beams are concrete filled steel box sections. This paper presents a capacity design principle for the seismic design of coupled composite plate shear wall–concrete filled (CC-PSW/CF) systems. The capacity design principle implements a strong wall–weak coupling beam approach, in which flexural yielding occurs in the coupling beams before flexural yielding at the base of walls. The coupling beams are sized to resist the calculated seismic lateral force level. The composite walls are sized to resist an amplified seismic lateral force corresponding to the overall plastic mechanism for the structure, while accounting for the capacity-limited forces from the coupling beams and the coupling action between the walls. The paper summarizes the recommendations and requirements for appropriate sizing of the composite coupling beams and walls. These recommendations were used along with the capacity design principle to design four example (8–22-story) structures and evaluate their seismic behavior. The structures were modeled using benchmarked finite-element models and fiber-based models that accounted for the various limit states, including steel yielding, local buckling, fracture, concrete crushing, confinement, and tension cracking. The numerical models were analyzed for monotonic pushover loading and scaled seismic ground motions. The structural responses from the nonlinear pushover analysis and the nonlinear time history analyses were in accordance with the capacity limited design philosophy, thus confirming its efficacy.
publisherASCE
titleCapacity Design of Coupled Composite Plate Shear Wall–Concrete-Filled System
typeJournal Paper
journal volume148
journal issue4
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)ST.1943-541X.0003296
journal fristpage04022022
journal lastpage04022022-18
page18
treeJournal of Structural Engineering:;2022:;Volume ( 148 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)