    Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading

    Source: Journal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 003::page 04021299
    Author:
    Dan Gan
    ,
    Feng Yan
    ,
    Zhiqiang Yang
    ,
    Zheng Zhou
    ,
    Rui Cheng
    DOI: 10.1061/(ASCE)ST.1943-541X.0003280
    Publisher: ASCE
    Abstract: This study proposes a through-beam composite joint system to connect square concrete-filled steel tubular (CFST) columns and concrete-filled U-shaped steel (CFUS) beams. In the joint system, channel-shaped holes in the square steel tube allow direct load transfer of the beam. Two procedures for constructing the joints, denoting two types of joint details (i.e., Type-I and Type-II), are proposed to facilitate field installation. Six cruciform joints were tested under combined constant axial compression and cyclic lateral loading. Three Type-I joints were tested. The main test parameters were the loading procedure and the axial load ratio applied on the CFST column. All Type-I specimens reached their beam flexural capacities followed by the fracture of fillet welds at beam ends, as well as the fracture of the reduced steel section within the joint zone. Three Type-II joints were constructed with the same column and beam section dimensions as the Type-I specimens. The main test parameters were the additional flexural rebars at beam ends and the axial load ratio. All Type-II specimens reached their beam flexural capacities, followed by the fracture of the heat-affected zone at beam ends. All specimens failed in a ductile manner, had favorable hysteretic performance, and complied with the acceptance criteria. Design considerations are proposed based on the test and analysis results.
    • Download: (3.832Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Behavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282414
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorDan Gan
    contributor authorFeng Yan
    contributor authorZhiqiang Yang
    contributor authorZheng Zhou
    contributor authorRui Cheng
    date accessioned2022-05-07T20:25:44Z
    date available2022-05-07T20:25:44Z
    date issued2021-12-28
    identifier other(ASCE)ST.1943-541X.0003280.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282414
    description abstractThis study proposes a through-beam composite joint system to connect square concrete-filled steel tubular (CFST) columns and concrete-filled U-shaped steel (CFUS) beams. In the joint system, channel-shaped holes in the square steel tube allow direct load transfer of the beam. Two procedures for constructing the joints, denoting two types of joint details (i.e., Type-I and Type-II), are proposed to facilitate field installation. Six cruciform joints were tested under combined constant axial compression and cyclic lateral loading. Three Type-I joints were tested. The main test parameters were the loading procedure and the axial load ratio applied on the CFST column. All Type-I specimens reached their beam flexural capacities followed by the fracture of fillet welds at beam ends, as well as the fracture of the reduced steel section within the joint zone. Three Type-II joints were constructed with the same column and beam section dimensions as the Type-I specimens. The main test parameters were the additional flexural rebars at beam ends and the axial load ratio. All Type-II specimens reached their beam flexural capacities, followed by the fracture of the heat-affected zone at beam ends. All specimens failed in a ductile manner, had favorable hysteretic performance, and complied with the acceptance criteria. Design considerations are proposed based on the test and analysis results.
    publisherASCE
    titleBehavior of CFST Column to Concrete-Filled U-Shaped Steel Beam Joints with Slabs under Cyclic Loading
    typeJournal Paper
    journal volume148
    journal issue3
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003280
    journal fristpage04021299
    journal lastpage04021299-19
    page19
    treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 003
    contenttypeFulltext