    Cyclic Experiments on Steel Sheet Connections for Standard CFS Framed Steel Sheet Sheathed Shear Walls

    Source: Journal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 002::page 04021261
    Author:
    Z. Zhang
    ,
    A. Singh
    ,
    F. Derveni
    ,
    S. Torabian
    ,
    K. D. Peterman
    ,
    T. C. Hutchinson
    ,
    B. W. Schafer
    DOI: 10.1061/(ASCE)ST.1943-541X.0003233
    Publisher: ASCE
    Abstract: The primary objective of this work is to provide connection-level force-deformation response appropriate for standard cold-formed steel (CFS) framed steel sheet sheathed shear walls under cyclic loads. Common CFS framing designs increasingly are exploring thicker framing options so that walls can meet gravity demands, overturning demands, and seismic overstrength requirements. For the seismic performance of self-drilling screw-fastened steel sheet sheathed shear walls, the cyclic nonlinear response of the screw-fastened connection is particularly important and should incorporate the impact of shear buckling of the steel sheet on the strength and ductility of the connection. Minimal cyclic connection-level shear test data exist, especially for combinations of screw-fastened thin steel sheet and thick framing steel. A unique lap shear test following current test standards was proposed to elucidate and characterize the cyclic screw-fastened connection behavior. An asymmetric cyclic loading protocol was selected with a small displacement applied in the direction that buckles the thin steel sheet, followed by progressively larger displacements in the opposite direction. A total of 93 tests were conducted, and characterization of the observed cyclic connection response with a multilinear backbone curve appropriate for use in models is provided. Connection strength is sensitive to whether the thin steel sheet ply is buckling away from or toward the fastener head in some test series. Performance of the screw shear strength as per the standard’s provisions is evaluated. The work is intended to provide critical missing information for CFS framed steel sheet sheathed shear walls for use in both simulation and design.
    • Download: (4.069Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Cyclic Experiments on Steel Sheet Connections for Standard CFS Framed Steel Sheet Sheathed Shear Walls

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282368
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorZ. Zhang
    contributor authorA. Singh
    contributor authorF. Derveni
    contributor authorS. Torabian
    contributor authorK. D. Peterman
    contributor authorT. C. Hutchinson
    contributor authorB. W. Schafer
    date accessioned2022-05-07T20:23:39Z
    date available2022-05-07T20:23:39Z
    date issued2021-11-22
    identifier other(ASCE)ST.1943-541X.0003233.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282368
    description abstractThe primary objective of this work is to provide connection-level force-deformation response appropriate for standard cold-formed steel (CFS) framed steel sheet sheathed shear walls under cyclic loads. Common CFS framing designs increasingly are exploring thicker framing options so that walls can meet gravity demands, overturning demands, and seismic overstrength requirements. For the seismic performance of self-drilling screw-fastened steel sheet sheathed shear walls, the cyclic nonlinear response of the screw-fastened connection is particularly important and should incorporate the impact of shear buckling of the steel sheet on the strength and ductility of the connection. Minimal cyclic connection-level shear test data exist, especially for combinations of screw-fastened thin steel sheet and thick framing steel. A unique lap shear test following current test standards was proposed to elucidate and characterize the cyclic screw-fastened connection behavior. An asymmetric cyclic loading protocol was selected with a small displacement applied in the direction that buckles the thin steel sheet, followed by progressively larger displacements in the opposite direction. A total of 93 tests were conducted, and characterization of the observed cyclic connection response with a multilinear backbone curve appropriate for use in models is provided. Connection strength is sensitive to whether the thin steel sheet ply is buckling away from or toward the fastener head in some test series. Performance of the screw shear strength as per the standard’s provisions is evaluated. The work is intended to provide critical missing information for CFS framed steel sheet sheathed shear walls for use in both simulation and design.
    publisherASCE
    titleCyclic Experiments on Steel Sheet Connections for Standard CFS Framed Steel Sheet Sheathed Shear Walls
    typeJournal Paper
    journal volume148
    journal issue2
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003233
    journal fristpage04021261
    journal lastpage04021261-17
    page17
    treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian