    Experimental Investigation on the Structural Performance of Mass Timber Panel-Concrete Composite Floors with Notched Connections

    Source: Journal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 002::page 04021249
    Author:
    Lei Zhang
    ,
    Jianhui Zhou
    ,
    Ying Hei Chui
    ,
    Douglas Tomlinson
    DOI: 10.1061/(ASCE)ST.1943-541X.0003229
    Publisher: ASCE
    Abstract: Mass timber panel (MTP)-concrete composite floors are gaining increasing interest from builders and designers due to their optimized structural performance, light self-weight, and aesthetically exposed wood ceilings. Among various connecting techniques between timber and concrete, notched connections made by cutting grooves on timber and filling them with concrete are considered as one of the most structurally efficient and cost-saving connecting solutions. Numerous ways of making and reinforcing the notched connections, however, hinder the standardization and development of the design guidelines for this type of connection, which reduces the competitiveness of MTP-concrete composite floors. In this study, experiments were carried out to investigate the performance of MTP-concrete composite floors with different connection designs. Nine composite floor specimens with varying span, connection number, notch depth, concrete thickness, and loading direction were designed and tested under bending. The bending stiffness, load-carrying capacity, ductility, and failure mode of tested specimens were studied and discussed. Test results show that the connection number, notch depth, and concrete thickness affect the bending stiffness and strength of the floor positively, an increase in floor span impacts the floor performance negatively, whereas the effect of a limited number of self-tapping screws in the notch is negligible. The study also shows that MTP-concrete composite floors with high strength, high stiffness, and good ductility can be achieved through the optimized design of notched connections.
    • Download: (3.720Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental Investigation on the Structural Performance of Mass Timber Panel-Concrete Composite Floors with Notched Connections

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282364
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorLei Zhang
    contributor authorJianhui Zhou
    contributor authorYing Hei Chui
    contributor authorDouglas Tomlinson
    date accessioned2022-05-07T20:23:24Z
    date available2022-05-07T20:23:24Z
    date issued2021-11-16
    identifier other(ASCE)ST.1943-541X.0003229.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282364
    description abstractMass timber panel (MTP)-concrete composite floors are gaining increasing interest from builders and designers due to their optimized structural performance, light self-weight, and aesthetically exposed wood ceilings. Among various connecting techniques between timber and concrete, notched connections made by cutting grooves on timber and filling them with concrete are considered as one of the most structurally efficient and cost-saving connecting solutions. Numerous ways of making and reinforcing the notched connections, however, hinder the standardization and development of the design guidelines for this type of connection, which reduces the competitiveness of MTP-concrete composite floors. In this study, experiments were carried out to investigate the performance of MTP-concrete composite floors with different connection designs. Nine composite floor specimens with varying span, connection number, notch depth, concrete thickness, and loading direction were designed and tested under bending. The bending stiffness, load-carrying capacity, ductility, and failure mode of tested specimens were studied and discussed. Test results show that the connection number, notch depth, and concrete thickness affect the bending stiffness and strength of the floor positively, an increase in floor span impacts the floor performance negatively, whereas the effect of a limited number of self-tapping screws in the notch is negligible. The study also shows that MTP-concrete composite floors with high strength, high stiffness, and good ductility can be achieved through the optimized design of notched connections.
    publisherASCE
    titleExperimental Investigation on the Structural Performance of Mass Timber Panel-Concrete Composite Floors with Notched Connections
    typeJournal Paper
    journal volume148
    journal issue2
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003229
    journal fristpage04021249
    journal lastpage04021249-16
    page16
    treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian