    Temperature Attained in Intumescent Coating–Protected Concrete-Filled Circular Steel Tubular Sections under the Standard Fire Condition

    Source: Journal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 001::page 04021224
    Author:
    M. Jafarian
    ,
    Y. C. Wang
    ,
    J. Yuan
    DOI: 10.1061/(ASCE)ST.1943-541X.0003130
    Publisher: ASCE
    Abstract: This paper presents the results of an experimental and numerical investigation to obtain a simplified analytical method to calculate intumescent coating thermal conductivity and temperatures of intumescent coating–protected concrete-filled circular steel tubular sections by using an equivalent section factor for the steel section without concrete infill. An important test of correctness of the equivalent steel section factor is that when the resulting thermal conductivity of the intumescent coatings is used in numerical modeling of concrete-filled sections, the steel and concrete core temperatures can be accurately calculated. This paper first reports the experimental results of 32 fire tests conducted on intumescent coating–protected concrete-filled circular sections; experimental variables included coating thickness and circular section dimensions. The fire test results are then used to assess the the accuracy of two existing methods of calculating the equivalent steel section factor. These methods were shown to give a wide range of effective thermal conductivity–temperature relationships for the same intumescent coating and not being able to accurately predict the steel and concrete core temperatures consistently. This paper then proposes a new equation to calculate the equivalent steel section factor, which is demonstrated to be able to more accurately predict the temperatures of intumescent coating–protected concrete-filled steel sections.
    • Download: (3.571Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Temperature Attained in Intumescent Coating–Protected Concrete-Filled Circular Steel Tubular Sections under the Standard Fire Condition

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282321
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorM. Jafarian
    contributor authorY. C. Wang
    contributor authorJ. Yuan
    date accessioned2022-05-07T20:21:37Z
    date available2022-05-07T20:21:37Z
    date issued2021-10-18
    identifier other(ASCE)ST.1943-541X.0003130.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282321
    description abstractThis paper presents the results of an experimental and numerical investigation to obtain a simplified analytical method to calculate intumescent coating thermal conductivity and temperatures of intumescent coating–protected concrete-filled circular steel tubular sections by using an equivalent section factor for the steel section without concrete infill. An important test of correctness of the equivalent steel section factor is that when the resulting thermal conductivity of the intumescent coatings is used in numerical modeling of concrete-filled sections, the steel and concrete core temperatures can be accurately calculated. This paper first reports the experimental results of 32 fire tests conducted on intumescent coating–protected concrete-filled circular sections; experimental variables included coating thickness and circular section dimensions. The fire test results are then used to assess the the accuracy of two existing methods of calculating the equivalent steel section factor. These methods were shown to give a wide range of effective thermal conductivity–temperature relationships for the same intumescent coating and not being able to accurately predict the steel and concrete core temperatures consistently. This paper then proposes a new equation to calculate the equivalent steel section factor, which is demonstrated to be able to more accurately predict the temperatures of intumescent coating–protected concrete-filled steel sections.
    publisherASCE
    titleTemperature Attained in Intumescent Coating–Protected Concrete-Filled Circular Steel Tubular Sections under the Standard Fire Condition
    typeJournal Paper
    journal volume148
    journal issue1
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003130
    journal fristpage04021224
    journal lastpage04021224-19
    page19
    treeJournal of Structural Engineering:;2021:;Volume ( 148 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian