YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Pipeline Systems Engineering and Practice
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Case Study of the Performance of Prestressed Concrete Cylinder Pipes in Northeastern Morocco

    Source: Journal of Pipeline Systems Engineering and Practice:;2022:;Volume ( 013 ):;issue: 002::page 05022002
    Author:
    Sara Hassi
    ,
    Mohamed Ebn Touhami
    ,
    Bruce Menu
    ,
    Hanane Benqlilou
    ,
    Adil Ejbouh
    DOI: 10.1061/(ASCE)PS.1949-1204.0000636
    Publisher: ASCE
    Abstract: This paper discusses the main causes of the severe deterioration of prestressed concrete cylinder pipes (PCCPs) used for potable water distribution in northeastern Morocco. A diagnostic study and in situ and laboratory tests were performed to gain some insight into the causes of the deterioration of PCCPs. Overall, it was found that the failure of PCCPs in the region is primarily the result of improper pipe joint installations, which allow water to leak from the pipes, allowing chlorides in the mortar coating to reach the prestressing wires inside the pipes and causing their corrosion. The mortar used to spray the prestressing wires was found to have been contaminated with chlorides during mixing by way of the mixing water, sand, and/or aggregates. The presence of sulfate ions in the mortar coating and the cyclical wetting and drying conditions of the region further accelerated corrosion rates. It was also found that poor bedding of pipes in the region’s marl soil resulted in differential settlement, causing high stress at joints, leading to cracking of the mortar coatings and corrosion of the prestressing wires and cylinders. The soil surrounding the pipes was, however, not found to be aggressive and there was no groundwater (at the buried depth of the PCCPs of approximately 2 m). The overall durability exposure class for the region was identified both as “cyclic wet and dry” and “moderately aggressive chemical environment” according to the Moroccan and European concrete standards.
    • Download: (4.568Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Case Study of the Performance of Prestressed Concrete Cylinder Pipes in Northeastern Morocco

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4282226
    Collections
    • Journal of Pipeline Systems Engineering and Practice

    Show full item record

    contributor authorSara Hassi
    contributor authorMohamed Ebn Touhami
    contributor authorBruce Menu
    contributor authorHanane Benqlilou
    contributor authorAdil Ejbouh
    date accessioned2022-05-07T20:17:09Z
    date available2022-05-07T20:17:09Z
    date issued2022-01-31
    identifier other(ASCE)PS.1949-1204.0000636.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4282226
    description abstractThis paper discusses the main causes of the severe deterioration of prestressed concrete cylinder pipes (PCCPs) used for potable water distribution in northeastern Morocco. A diagnostic study and in situ and laboratory tests were performed to gain some insight into the causes of the deterioration of PCCPs. Overall, it was found that the failure of PCCPs in the region is primarily the result of improper pipe joint installations, which allow water to leak from the pipes, allowing chlorides in the mortar coating to reach the prestressing wires inside the pipes and causing their corrosion. The mortar used to spray the prestressing wires was found to have been contaminated with chlorides during mixing by way of the mixing water, sand, and/or aggregates. The presence of sulfate ions in the mortar coating and the cyclical wetting and drying conditions of the region further accelerated corrosion rates. It was also found that poor bedding of pipes in the region’s marl soil resulted in differential settlement, causing high stress at joints, leading to cracking of the mortar coatings and corrosion of the prestressing wires and cylinders. The soil surrounding the pipes was, however, not found to be aggressive and there was no groundwater (at the buried depth of the PCCPs of approximately 2 m). The overall durability exposure class for the region was identified both as “cyclic wet and dry” and “moderately aggressive chemical environment” according to the Moroccan and European concrete standards.
    publisherASCE
    titleCase Study of the Performance of Prestressed Concrete Cylinder Pipes in Northeastern Morocco
    typeJournal Paper
    journal volume13
    journal issue2
    journal titleJournal of Pipeline Systems Engineering and Practice
    identifier doi10.1061/(ASCE)PS.1949-1204.0000636
    journal fristpage05022002
    journal lastpage05022002-15
    page15
    treeJournal of Pipeline Systems Engineering and Practice:;2022:;Volume ( 013 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian