Show simple item record

contributor authorYang, Bo
contributor authorKlineberg, Eric
contributor authorO'Connell, Grace D.
date accessioned2022-02-06T05:27:42Z
date available2022-02-06T05:27:42Z
date copyright4/21/2021 12:00:00 AM
date issued2021
identifier issn0148-0731
identifier otherbio_143_08_081002.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278075
description abstractPainful herniated discs are treated surgically by removing extruded nucleus pulposus (NP) material (nucleotomy). NP removal through enzymatic digestion is also commonly performed to initiate degenerative changes to study potential biological repair strategies. Experimental and computational studies have shown a decrease in disc stiffness with nucleotomy under single loading modalities, such as compression-only or bending-only loading. However, studies that apply more physiologically relevant loading conditions, such as compression in combination with bending or torsion, have shown contradicting results. We used a previously validated bone–disc–bone finite element model (Control) to create a Nucleotomy model to evaluate the effect of dual loading conditions (compression with torsion or bending) on intradiscal deformations. While disc joint stiffness decreased with nucleotomy under single loading conditions, as commonly reported in the literature, dual loading resulted in an increase in bending stiffness. More specifically, dual loading resulted in a 40% increase in bending stiffness under flexion and extension and a 25% increase in stiffness under lateral bending. The increase in bending stiffness was due to an increase and shift in compressive stress, where peak stresses migrated from the NP–annulus interface to the outer annulus. In contrast, the decrease in torsional stiffness was due to greater fiber reorientation during compression. In general, large radial strains were observed with nucleotomy, suggesting an increased risk for delamination or degenerative remodeling. In conclusion, the effect of nucleotomy on disc mechanics depends on the type and complexity of applied loads.
publisherThe American Society of Mechanical Engineers (ASME)
titleIntervertebral Disc Mechanics With Nucleotomy: Differences Between Simple and Dual Loading
typeJournal Paper
journal volume143
journal issue8
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4050538
journal fristpage081002-1
journal lastpage081002-10
page10
treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 008
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record