Show simple item record

contributor authorWhittal, Mitchel C.
contributor authorMolladavoodi, Sara
contributor authorZwambag, Derek P.
contributor authorMillecamps, Magali
contributor authorStone, Laura S.
contributor authorGregory, Diane E.
date accessioned2022-02-05T22:23:20Z
date available2022-02-05T22:23:20Z
date copyright10/8/2020 12:00:00 AM
date issued2020
identifier issn0148-0731
identifier otherbio_143_02_024501.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4277448
description abstractIntervertebral disc (IVD) degeneration is associated with low back pain (LBP) and accompanied by mechanical changes to the spine. Secreted protein acidic and rich in cysteine (SPARC) is a protein that contributes to the functioning and maintenance of the extracellular matrix. SPARC-null mice display accelerated IVD degeneration and pain-associated behaviors. This study examined if SPARC-null mice also display altered spine mechanics as compared to wild-type (WT) mice. Lumbar spines from SPARC-null (n = 36) and WT (n = 18) mice aged 14–25 months were subjected to cyclic axial tension and compression to determine neutral zone (NZ) length and stiffness. Three separate mechanical tests were completed for each spine to determine the effect of the number of IVDs tested in series (one versus two versus three IVDs). SPARC-null spine NZs were both stiffer (p < 0.001) and smaller in length (p < 0.001) than WT spines. There was an effect of the number of IVDs tested in series for NZ length but not NZ stiffness when collapsed across condition (SPARC-null and WT). Correlation analysis revealed a weak negative correlation (r = −0.24) between age and NZ length in SPARC-null mice and a weak positive correlation (r = 0.30) between age and NZ stiffness in WT mice. In conclusion, SPARC-null mice had stiffer and smaller NZs than WT mice, regardless of the number of IVDs in series being tested. The increased stiffness of these IVDs likely influences mobility at these spinal joints thereby potentially contributing to low back pain.
publisherThe American Society of Mechanical Engineers (ASME)
titleMechanical Consequence of Induced Intervertebral Disc Degeneration in the SPARC-Null Mouse
typeJournal Paper
journal volume143
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4047995
journal fristpage024501-1
journal lastpage024501-4
page4
treeJournal of Biomechanical Engineering:;2020:;volume( 143 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record