Show simple item record

contributor authorWerder, Tobias
contributor authorLiebich, Robert
contributor authorNeuhäuser, Karl
contributor authorBehnsen, Clara
contributor authorKing, Rudibert
date accessioned2022-02-05T22:07:18Z
date available2022-02-05T22:07:18Z
date copyright2/2/2021 12:00:00 AM
date issued2021
identifier issn0889-504X
identifier otherturbo_143_2_021008.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276954
description abstractAs a consequence of constant volume combustion in gas turbines, pressure waves propagating upstream the main flow into the compressor system are generated leading to incidence variations. Numerical and experimental investigations of stator vanes have shown that active flow control (AFC) by means of adaptive blade geometries is beneficial when such periodic incidence variations occur. A significant risk reduction in a compressor facing disturbances can thereby be achieved concerning stall or choke. Experimental investigations on such an AFC method with simultaneous application of a closed-loop control are missing in order to demonstrate its potential. This work investigates a linear compressor cascade that is equipped with a 3D-manufactured piezo-adaptive blade structure. The utilized actuators are piezoelectric macro-fiber-composites. A throttling device is positioned downstream the trailing edge plane to emulate an unsteady combustion process. Periodic transient throttling events with a frequency of up to 20 Hz cause incidence changes to the blade’s leading edge. Consequently, pressure fluctuations on the blade’s surface occur, having a significant impact on the pressure recovery downstream of the stator cascade. Experimental results of harmonically actuating the piezo-adaptive blade with the corresponding disturbance frequency show that the impact of disturbances can be reduced to approximately 50%. However, this is only effective if the phase shift of the harmonic actuation is adjusted correctly. Using an inadequate phase shift reverses the positive effects, causing the aforementioned stall, choke, or significant losses. In order to find the optimum phase shift, even under varying, possibly unpredictable operating conditions, an extremum seeking controller is presented. This gradient-based approach is minimizing the pressure variance over time by carefully adjusting the phase shift of the harmonic actuation of the AFC system.
publisherThe American Society of Mechanical Engineers (ASME)
titleActive Flow Control Utilizing an Adaptive Blade Geometry and an Extremum Seeking Algorithm at Periodically Transient Boundary Conditions
typeJournal Paper
journal volume143
journal issue2
journal titleJournal of Turbomachinery
identifier doi10.1115/1.4049787
journal fristpage021008-1
journal lastpage021008-6
page6
treeJournal of Turbomachinery:;2021:;volume( 143 ):;issue: 002
contenttypeFulltext