Show simple item record

contributor authorAcharya, Shashank
contributor authorKou, Wenjun
contributor authorHalder, Sourav
contributor authorCarlson, Dustin A.
contributor authorKahrilas, Peter J.
contributor authorPandolfino, John E.
contributor authorPatankar, Neelesh A.
date accessioned2022-02-05T21:44:26Z
date available2022-02-05T21:44:26Z
date copyright3/24/2021 12:00:00 AM
date issued2021
identifier issn0148-0731
identifier otherbio_143_07_071001.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276245
description abstractBalloon dilation catheters are often used to quantify the physiological state of peristaltic activity in tubular organs and comment on their ability to propel fluid which is important for healthy human function. To fully understand this system's behavior, we analyzed the effect of a solitary peristaltic wave on a fluid-filled elastic tube with closed ends. A reduced order model that predicts the resulting tube wall deformations, flow velocities, and pressure variations is presented. This simplified model is compared with detailed fluid–structure three-dimensional (3D) immersed boundary (IB) simulations of peristaltic pumping in tube walls made of hyperelastic material. The major dynamics observed in the 3D simulations were also displayed by our one-dimensional (1D) model under laminar flow conditions. Using the 1D model, several pumping regimes were investigated and presented in the form of a regime map that summarizes the system's response for a range of physiological conditions. Finally, the amount of work done during a peristaltic event in this configuration was defined and quantified. The variation of elastic energy and work done during pumping was found to have a unique signature for each regime. An extension of the 1D model is applied to enhance patient data collected by the device and find the work done for a typical esophageal peristaltic wave. This detailed characterization of the system's behavior aids in better interpreting the clinical data obtained from dilation catheters. Additionally, the pumping capacity of the esophagus can be quantified for comparative studies between disease groups.
publisherThe American Society of Mechanical Engineers (ASME)
titlePumping Patterns and Work Done During Peristalsis in Finite-Length Elastic Tubes
typeJournal Paper
journal volume143
journal issue7
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4050284
journal fristpage071001-1
journal lastpage071001-13
page13
treeJournal of Biomechanical Engineering:;2021:;volume( 143 ):;issue: 007
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record