Show simple item record

contributor authorElliott, Winston
contributor authorGuo, Dongjie
contributor authorVeldtman, Gruschen
contributor authorTan, Wei
date accessioned2022-02-04T23:03:43Z
date available2022-02-04T23:03:43Z
date copyright4/1/2020 12:00:00 AM
date issued2020
identifier issn0148-0731
identifier otherbio_142_04_041001.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4276018
description abstractTime-dependent arterial wall property is an important but difficult topic in vascular mechanics. Hysteresis, which appears during the measurement of arterial pressure–diameter relationship through a cardiac cycle, has been used to indicate time-dependent mechanics of arteries. However, the cause–effect relationship between viscoelastic (VE) properties of the arterial wall and hemodynamics, particularly the viscous contribution to hemodynamics, remains challenging. Herein, we show direct comparisons between elastic (E) (loss/storage < 0.1) and highly viscoelastic (loss/storage > 0.45) conduit structures with arterial-like compliance, in terms of their capability of altering pulsatile flow, wall shear, and energy level. Conduits were made from varying ratio of vinyl- and methyl-terminated poly(dimethylsiloxane) and were fit in a mimetic circulatory system measuring volumetric flow, pressure, and strain. Results indicated that when compared to elastic conduits, viscoelastic conduits attenuated lumen distension waveforms, producing an average of 11% greater cross-sectional area throughout a mimetic cardiac cycle. In response to such changes in lumen diameter strain, pressure and volumetric flow waves in viscoelastic conduits decreased by 3.9% and 6%, respectively, in the peak-to-peak amplitude. Importantly, the pulsatile waveforms for both diameter strain and volumetric flow demonstrated greater temporal alignment in viscoelastic conduits due to pulsation attenuation, resulting in 25% decrease in the oscillation of wall shear stress (WSS). We hope these findings may be used to further examine time-dependent arterial properties in disease prognosis and progression, as well as their use in vascular graft design.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of Viscoelasticity on Arterial-Like Pulsatile Flow Dynamics and Energy
typeJournal Paper
journal volume142
journal issue4
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4044877
journal fristpage041001-1
journal lastpage041001-12
page12
treeJournal of Biomechanical Engineering:;2020:;volume( 142 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record