contributor authorWalsh, Conor J.
contributor authorVasilyev, Nikolay V.
date accessioned2022-02-04T22:15:11Z
date available2022-02-04T22:15:11Z
date copyright5/20/2020 12:00:00 AM
date issued2020
identifier issn1932-6181
identifier othermed_014_03_031003.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275192
description abstractSoft robotic devices have been proposed as an alternative solution for ventricular assistance. Unlike conventional ventricular assist devices (VADs) that pump blood through an artificial lumen, soft robotic VADs (SRVADs) use pneumatic artificial muscles (PAM) to assist native contraction and relaxation of the ventricle. Synchronization of SRVADs is critical to ensure maximized and physiologic cardiac output. We developed a proof-of-concept synchronization algorithm that uses an epicardial electrogram as an input signal and evaluated the approach on adult Yorkshire pigs (n = 2). An SRVAD previously developed by our group was implanted on the right ventricle (RV). We demonstrated an improvement in the synchronization of the SRVAD using an epicardial electrogram signal versus a RV pressure signal of 4 ± 0.5% in heart failure and 3.2 ± 0.5% during actuation for animal 1 and 7.4 ± 0.6% in heart failure and 8.2% ± 0.8% during actuation for animal 2. Results suggest that improved synchronization is translated in greater cardiac output. The pulmonary artery (PA) flow was restored to a 107% and 106% of the healthy baseline during RV electrogram actuation and RV pressure actuation, respectively, in animal 1, and to a 100% and 87% in animal 2. Therefore, the presented system using the RV electrogram signal as a control input has shown to be superior in comparison with the use of the RV pressure signal.
publisherThe American Society of Mechanical Engineers (ASME)
titleSynchronization of a Soft Robotic Ventricular Assist Device to the Native Cardiac Rhythm Using an Epicardial Electrogram
typeJournal Paper
journal volume14
journal issue3
journal titleJournal of Medical Devices
identifier doi10.1115/1.4047114
journal fristpage031003-1
journal lastpage031003-8
page8
treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 003