Show simple item record

contributor authorWilson, Brandon M.
contributor authorKoskelo, Aaron
date accessioned2022-02-04T14:36:49Z
date available2022-02-04T14:36:49Z
date copyright2020/04/10/
date issued2020
identifier issn2377-2158
identifier othervvuq_005_01_011004.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274029
description abstractValidation assessments should respond to a diverse set of stakeholders, each with different questions and needs relevant to validation. A single metric designed to address each validation need can inadvertently lead to convoluted, misleading interpretations, especially as individual stakeholders interpret the details of the assessment in terms of their own (often unevaluated) intended use. We propose a validation assessment workflow composed of four necessary and distinct components: (1) model accuracy, (2) model acceptability, (3) validation evaluation, and (4) validation recommendations. We discuss the necessity and purpose of each component in the validation workflow and demonstrate the intent of each component with an example from high-energy-density physics.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Practical Validation Assessment Workflow
typeJournal Paper
journal volume5
journal issue1
journal titleJournal of Verification, Validation and Uncertainty Quantification
identifier doi10.1115/1.4046787
page11004
treeJournal of Verification, Validation and Uncertainty Quantification:;2020:;volume( 005 ):;issue: 001
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record