YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    In-Plane Shear Cyclic Performance of Spline Cross-Laminated Timber-Concrete Composite Diaphragms

    Source: Journal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 010::page 04021148-1
    Author:
    Bradly Taylor
    ,
    Andre R. Barbosa
    ,
    Arijit Sinha
    DOI: 10.1061/(ASCE)ST.1943-541X.0003127
    Publisher: ASCE
    Abstract: Over the past decade, cross-laminated timber (CLT) panels have gained popularity worldwide. To achieve larger spans and to increase the resistance to diaphragm seismic and wind forces to be transferred through CLT floor or roof systems, CLT-concrete composite (CCC) floors have been developed as an alternative. While significant testing has been performed under gravity loading, limited experimental data exist on the in-plane performance of CCC systems. This study presents results from an experimental program designed to characterize the in-plane shear behavior of CCC diaphragm connections using different CLT to concrete screw connector orientations in a test setup that simulates the expected seismic load path in diaphragms for platform-type construction. Tested variables include concrete slab thickness, composite screw angle, and single spline connection systems consisting of nails or screws. Experimental results and observed damage progression from cyclic testing are presented and discussed. Results indicate that CCC systems achieved increased stiffness and strength values when compared to bare-CLT systems, but slab thickness did not influence the strength and stiffness of the system for the load paths simulated. Additionally, CCC floor systems with 45° composite screw connectors displayed increased strength but overall similar stiffness values when compared to the CCC systems with 90° composite screws. The results provide useful engineering parameters, such as elastic stiffness, peak load, displacement capacity, and ductility ratios that can be used in the development of codified design parameters or in performance-based designs.
    • Download: (2.954Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      In-Plane Shear Cyclic Performance of Spline Cross-Laminated Timber-Concrete Composite Diaphragms

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4272773
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorBradly Taylor
    contributor authorAndre R. Barbosa
    contributor authorArijit Sinha
    date accessioned2022-02-01T22:10:43Z
    date available2022-02-01T22:10:43Z
    date issued10/1/2021
    identifier other%28ASCE%29ST.1943-541X.0003127.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4272773
    description abstractOver the past decade, cross-laminated timber (CLT) panels have gained popularity worldwide. To achieve larger spans and to increase the resistance to diaphragm seismic and wind forces to be transferred through CLT floor or roof systems, CLT-concrete composite (CCC) floors have been developed as an alternative. While significant testing has been performed under gravity loading, limited experimental data exist on the in-plane performance of CCC systems. This study presents results from an experimental program designed to characterize the in-plane shear behavior of CCC diaphragm connections using different CLT to concrete screw connector orientations in a test setup that simulates the expected seismic load path in diaphragms for platform-type construction. Tested variables include concrete slab thickness, composite screw angle, and single spline connection systems consisting of nails or screws. Experimental results and observed damage progression from cyclic testing are presented and discussed. Results indicate that CCC systems achieved increased stiffness and strength values when compared to bare-CLT systems, but slab thickness did not influence the strength and stiffness of the system for the load paths simulated. Additionally, CCC floor systems with 45° composite screw connectors displayed increased strength but overall similar stiffness values when compared to the CCC systems with 90° composite screws. The results provide useful engineering parameters, such as elastic stiffness, peak load, displacement capacity, and ductility ratios that can be used in the development of codified design parameters or in performance-based designs.
    publisherASCE
    titleIn-Plane Shear Cyclic Performance of Spline Cross-Laminated Timber-Concrete Composite Diaphragms
    typeJournal Paper
    journal volume147
    journal issue10
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0003127
    journal fristpage04021148-1
    journal lastpage04021148-14
    page14
    treeJournal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian