    Causes of Failure and Strengthening Measures of a Pile Foundation Supporting Transmission Line Tower

    Source: Journal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 004::page 04021034-1
    Author:
    Vaibhav Mittal
    ,
    Manojit Samanta
    DOI: 10.1061/(ASCE)CF.1943-5509.0001592
    Publisher: ASCE
    Abstract: The present paper describes the failure of an under-reamed pile foundation supporting a transmission line tower. Assessment of in-service pile conditions, i.e., in-built length, depth of bulb, uniformity of cross-sectional area, and length of the pile, are estimated through low strain integrity test. Integrity test results reveal that improper bulb formation and shorter as-built length than the designed are the leading causes of failure. Different performance criteria (uplift, compressive, and lateral capacities) of the in-service pile foundation are estimated through extensive finite element analysis and conventional approaches. Different geometric characteristics, i.e., straight shaft, different diameter of the bulb, and pile length, are simulated to represent the in-service pile conditions in the field. The estimated performance criteria are compared with the initial design values to evaluate the required degree of strengthening measures. The paper presents the initial design criteria of pile, soil condition, low strain integrity test, finite element modeling, and strengthening measures of the pile foundation to ensure the long-term stability of the transmission tower.
    • Download: (1.909Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Causes of Failure and Strengthening Measures of a Pile Foundation Supporting Transmission Line Tower

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270938
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorVaibhav Mittal
    contributor authorManojit Samanta
    date accessioned2022-02-01T00:06:56Z
    date available2022-02-01T00:06:56Z
    date issued8/1/2021
    identifier other%28ASCE%29CF.1943-5509.0001592.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270938
    description abstractThe present paper describes the failure of an under-reamed pile foundation supporting a transmission line tower. Assessment of in-service pile conditions, i.e., in-built length, depth of bulb, uniformity of cross-sectional area, and length of the pile, are estimated through low strain integrity test. Integrity test results reveal that improper bulb formation and shorter as-built length than the designed are the leading causes of failure. Different performance criteria (uplift, compressive, and lateral capacities) of the in-service pile foundation are estimated through extensive finite element analysis and conventional approaches. Different geometric characteristics, i.e., straight shaft, different diameter of the bulb, and pile length, are simulated to represent the in-service pile conditions in the field. The estimated performance criteria are compared with the initial design values to evaluate the required degree of strengthening measures. The paper presents the initial design criteria of pile, soil condition, low strain integrity test, finite element modeling, and strengthening measures of the pile foundation to ensure the long-term stability of the transmission tower.
    publisherASCE
    titleCauses of Failure and Strengthening Measures of a Pile Foundation Supporting Transmission Line Tower
    typeJournal Paper
    journal volume35
    journal issue4
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001592
    journal fristpage04021034-1
    journal lastpage04021034-11
    page11
    treeJournal of Performance of Constructed Facilities:;2021:;Volume ( 035 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian