YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Composites for Construction
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Development Length of Small-Diameter Basalt FRP Bars in Normal- and High-Strength Concrete

    Source: Journal of Composites for Construction:;2021:;Volume ( 025 ):;issue: 001::page 04020086-1
    Author:
    Decebal Michaud
    ,
    Amir Fam
    DOI: 10.1061/(ASCE)CC.1943-5614.0001107
    Publisher: ASCE
    Abstract: Small-diameter fiber-reinforced polymer (FRP) bars have great potential in certain applications, such as concrete sandwich panels, ties, and shear connectors. In this study, the development lengths (Ld) of basalt FRP (BFRP) deformed bars of 4–8 mm diameter (db) will be determined through a series of 44 notched beam tests with concrete of 41–70 MPa compressive strength. The beams measured 101 × 203 mm in cross section and varied in length from 610 to 1,980 mm to accommodate various embedment lengths (Le). Depending on db, Le varied from 5 to 109 db and the clear concrete cover was 30 mm. Bond failure of the 4 and 6 mm bars was by pullout and that of the 8 mm bar was by concrete splitting. The bar axial stress at failure will be plotted against Le for each set and linear regression will be used to establish Ld based on the guaranteed tensile strength. It was shown that as concrete strength increased from 41 to 70 MPa, Ld reduced from 32 to 20 db for the 4 mm bar, from 30 to 25 db for the 6 mm bar, and from 52 to 23 db for the 8 mm bar. The average bond strength increased as the Le shortened, and as concrete strength increased. ACI 440.R1 (ACI 2015) and CAN/CSA S806 (CSA 2012) design guides grossly overestimated Ld of these small-diameter bars. Alternative equations are proposed for both splitting and pullout bond failure that provided more accurate predictions of Ld.
    • Download: (1.960Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Development Length of Small-Diameter Basalt FRP Bars in Normal- and High-Strength Concrete

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270801
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorDecebal Michaud
    contributor authorAmir Fam
    date accessioned2022-02-01T00:02:35Z
    date available2022-02-01T00:02:35Z
    date issued2/1/2021
    identifier other%28ASCE%29CC.1943-5614.0001107.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270801
    description abstractSmall-diameter fiber-reinforced polymer (FRP) bars have great potential in certain applications, such as concrete sandwich panels, ties, and shear connectors. In this study, the development lengths (Ld) of basalt FRP (BFRP) deformed bars of 4–8 mm diameter (db) will be determined through a series of 44 notched beam tests with concrete of 41–70 MPa compressive strength. The beams measured 101 × 203 mm in cross section and varied in length from 610 to 1,980 mm to accommodate various embedment lengths (Le). Depending on db, Le varied from 5 to 109 db and the clear concrete cover was 30 mm. Bond failure of the 4 and 6 mm bars was by pullout and that of the 8 mm bar was by concrete splitting. The bar axial stress at failure will be plotted against Le for each set and linear regression will be used to establish Ld based on the guaranteed tensile strength. It was shown that as concrete strength increased from 41 to 70 MPa, Ld reduced from 32 to 20 db for the 4 mm bar, from 30 to 25 db for the 6 mm bar, and from 52 to 23 db for the 8 mm bar. The average bond strength increased as the Le shortened, and as concrete strength increased. ACI 440.R1 (ACI 2015) and CAN/CSA S806 (CSA 2012) design guides grossly overestimated Ld of these small-diameter bars. Alternative equations are proposed for both splitting and pullout bond failure that provided more accurate predictions of Ld.
    publisherASCE
    titleDevelopment Length of Small-Diameter Basalt FRP Bars in Normal- and High-Strength Concrete
    typeJournal Paper
    journal volume25
    journal issue1
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0001107
    journal fristpage04020086-1
    journal lastpage04020086-11
    page11
    treeJournal of Composites for Construction:;2021:;Volume ( 025 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian