YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Bridge Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental and Numerical Assessment of Precast Bridge Columns with Different Grouted Splice Sleeve Coupler Designs Based on Shake Table Test

    Source: Journal of Bridge Engineering:;2021:;Volume ( 026 ):;issue: 008::page 04021055-1
    Author:
    Hongya Qu
    ,
    Jixing Fu
    ,
    Tiantian Li
    ,
    Chengjun Wu
    ,
    Xianfeng Sun
    ,
    Hongyi Wei
    ,
    Zhiqiang Wang
    DOI: 10.1061/(ASCE)BE.1943-5592.0001748
    Publisher: ASCE
    Abstract: In this study, the seismic performance of a precast bridge substructure from an urban viaduct is investigated via shake table tests. A simple beam bridge is formed by using two precast bridge pier specimens, and one pier is implemented with an improved grouted splice sleeve coupler (GSSC) design with a shallow recess in the footing for achieving better integrity, while the other is implemented with a conventional GSSC in the pier and flat grouting bed. The two precast bridge pier specimens are first compared with each other. Another bridge specimen is then created and compared, which is supported by two cast-in-place (CIP) references with identical dimensions and mild rebars. The two bridge specimens are first tested with an isolated bearing system, followed by the fixed bearing system. From the test results, it is revealed that the isolated system with lead-rubber bearings retains good seismic isolation capability. The damage to the plastic hinge region of the CIP specimens is more severe with rebar buckling, while the strengthening effect of the GSSC elements in the pier prevents the rebars of the precast specimens from buckling. The GSSCs also limit the peak lateral displacement of the precast columns and redistribute the strain values along the longitudinal rebars. Finally, finite-element models are developed by OpenSEES with fiber elements and alternative bond–slip simulation approaches, which are in acceptable correlation with the test results.
    • Download: (2.490Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Experimental and Numerical Assessment of Precast Bridge Columns with Different Grouted Splice Sleeve Coupler Designs Based on Shake Table Test

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270624
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorHongya Qu
    contributor authorJixing Fu
    contributor authorTiantian Li
    contributor authorChengjun Wu
    contributor authorXianfeng Sun
    contributor authorHongyi Wei
    contributor authorZhiqiang Wang
    date accessioned2022-01-31T23:56:51Z
    date available2022-01-31T23:56:51Z
    date issued8/1/2021
    identifier other%28ASCE%29BE.1943-5592.0001748.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270624
    description abstractIn this study, the seismic performance of a precast bridge substructure from an urban viaduct is investigated via shake table tests. A simple beam bridge is formed by using two precast bridge pier specimens, and one pier is implemented with an improved grouted splice sleeve coupler (GSSC) design with a shallow recess in the footing for achieving better integrity, while the other is implemented with a conventional GSSC in the pier and flat grouting bed. The two precast bridge pier specimens are first compared with each other. Another bridge specimen is then created and compared, which is supported by two cast-in-place (CIP) references with identical dimensions and mild rebars. The two bridge specimens are first tested with an isolated bearing system, followed by the fixed bearing system. From the test results, it is revealed that the isolated system with lead-rubber bearings retains good seismic isolation capability. The damage to the plastic hinge region of the CIP specimens is more severe with rebar buckling, while the strengthening effect of the GSSC elements in the pier prevents the rebars of the precast specimens from buckling. The GSSCs also limit the peak lateral displacement of the precast columns and redistribute the strain values along the longitudinal rebars. Finally, finite-element models are developed by OpenSEES with fiber elements and alternative bond–slip simulation approaches, which are in acceptable correlation with the test results.
    publisherASCE
    titleExperimental and Numerical Assessment of Precast Bridge Columns with Different Grouted Splice Sleeve Coupler Designs Based on Shake Table Test
    typeJournal Paper
    journal volume26
    journal issue8
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001748
    journal fristpage04021055-1
    journal lastpage04021055-18
    page18
    treeJournal of Bridge Engineering:;2021:;Volume ( 026 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian