    Statistical Investigation on the Temperature Actions of CFST Truss Based on Long-Term Measurement

    Source: Journal of Bridge Engineering:;2021:;Volume ( 026 ):;issue: 008::page 04021045-1
    Author:
    Jiang Liu
    ,
    Yongjian Liu
    ,
    Xinkai Yan
    ,
    Guojing Zhang
    DOI: 10.1061/(ASCE)BE.1943-5592.0001740
    Publisher: ASCE
    Abstract: Concrete-filled steel tube (CFST) trusses are the most common elements used in long-span CFST bridges; however, the temperature actions have not been systematically investigated. This paper presents a long-term temperature measurement on a CFST truss segment and decompose its temperature actions into uniform temperature, vertical temperature difference (VTD) between upper and lower chords, and lateral temperature difference (LTD) between left and right chords. Based on the recorded long-term meteorological data, empirical formulae were established to predict these temperature actions and prove with a high degree of confidence. Subsequently, an effective extreme value analysis (EVA) based on the Monte Carlo method was presented to calculate the representative values of these temperature actions. All these values are greater than the recommended values in the Chinese Code Specification. Based on a series of frequency analysis on each temperature action, three potential combinations were finally determined. The combinations were all input into a frame finite-element model of a 220 m span CFST arch bridge for the thermal response calculation and comparisons with the Specification temperature actions and dead load. These efforts suggest that the investigative methodology and the proposed temperature action combinations can expand the provisions of the Chinese Code Specification and are more suitable for the thermal response calculation and design of CFST arch bridges with a truss arch rib.
    • Download: (3.089Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Statistical Investigation on the Temperature Actions of CFST Truss Based on Long-Term Measurement

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270557
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorJiang Liu
    contributor authorYongjian Liu
    contributor authorXinkai Yan
    contributor authorGuojing Zhang
    date accessioned2022-01-31T23:54:20Z
    date available2022-01-31T23:54:20Z
    date issued8/1/2021
    identifier other%28ASCE%29BE.1943-5592.0001740.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270557
    description abstractConcrete-filled steel tube (CFST) trusses are the most common elements used in long-span CFST bridges; however, the temperature actions have not been systematically investigated. This paper presents a long-term temperature measurement on a CFST truss segment and decompose its temperature actions into uniform temperature, vertical temperature difference (VTD) between upper and lower chords, and lateral temperature difference (LTD) between left and right chords. Based on the recorded long-term meteorological data, empirical formulae were established to predict these temperature actions and prove with a high degree of confidence. Subsequently, an effective extreme value analysis (EVA) based on the Monte Carlo method was presented to calculate the representative values of these temperature actions. All these values are greater than the recommended values in the Chinese Code Specification. Based on a series of frequency analysis on each temperature action, three potential combinations were finally determined. The combinations were all input into a frame finite-element model of a 220 m span CFST arch bridge for the thermal response calculation and comparisons with the Specification temperature actions and dead load. These efforts suggest that the investigative methodology and the proposed temperature action combinations can expand the provisions of the Chinese Code Specification and are more suitable for the thermal response calculation and design of CFST arch bridges with a truss arch rib.
    publisherASCE
    titleStatistical Investigation on the Temperature Actions of CFST Truss Based on Long-Term Measurement
    typeJournal Paper
    journal volume26
    journal issue8
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001740
    journal fristpage04021045-1
    journal lastpage04021045-16
    page16
    treeJournal of Bridge Engineering:;2021:;Volume ( 026 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian