    Ultimate Bearing Capacity of Unconfined Bolted Connections in Cold-Formed Steel Members

    Source: Journal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 005::page 04021048-1
    Author:
    Refat A. Bhuiyan
    ,
    Aziz Ahmed
    ,
    Lip H. Teh
    DOI: 10.1061/(ASCE)ST.1943-541X.0002992
    Publisher: ASCE
    Abstract: The commentary to the North American cold-formed steel specification recommends physical testing to determine the performance of a bolted connection where the plies are not in contact with each other. This paper presents the laboratory test results of 120 such specimens with sheet thicknesses ranging from 0.55 to 3.0 mm, bolted with 10-, 12-, or 16-mm bolts. Finite-element analyses support the experimental finding that the bearing failure of an unconfined bolted connection is not associated with shear fracture but with crimpling of the critical ply. The bearing capacity varies with the square root of the bolt diameter and nonlinearly with the sheet thickness. Dimensionally consistent and continuous design equations are derived and verified against the results of the laboratory tests and finite-element analyses, the latter supplementing the former with configurations involving 8-mm bolts. The derived relationships between the bearing capacity and the sheet thickness and bolt diameter are also verified against 18 independent test results involving bolted connections through square hollow sections. The presented equation is significantly simpler but more accurate than those proposed in the literature for such connections. A resistance factor of 0.70 is recommended for use with the proposed design equations for determining the bearing capacities of unconfined bolted connections.
    • Download: (996.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Ultimate Bearing Capacity of Unconfined Bolted Connections in Cold-Formed Steel Members

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4270364
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorRefat A. Bhuiyan
    contributor authorAziz Ahmed
    contributor authorLip H. Teh
    date accessioned2022-01-31T23:47:36Z
    date available2022-01-31T23:47:36Z
    date issued5/1/2021
    identifier other%28ASCE%29ST.1943-541X.0002992.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4270364
    description abstractThe commentary to the North American cold-formed steel specification recommends physical testing to determine the performance of a bolted connection where the plies are not in contact with each other. This paper presents the laboratory test results of 120 such specimens with sheet thicknesses ranging from 0.55 to 3.0 mm, bolted with 10-, 12-, or 16-mm bolts. Finite-element analyses support the experimental finding that the bearing failure of an unconfined bolted connection is not associated with shear fracture but with crimpling of the critical ply. The bearing capacity varies with the square root of the bolt diameter and nonlinearly with the sheet thickness. Dimensionally consistent and continuous design equations are derived and verified against the results of the laboratory tests and finite-element analyses, the latter supplementing the former with configurations involving 8-mm bolts. The derived relationships between the bearing capacity and the sheet thickness and bolt diameter are also verified against 18 independent test results involving bolted connections through square hollow sections. The presented equation is significantly simpler but more accurate than those proposed in the literature for such connections. A resistance factor of 0.70 is recommended for use with the proposed design equations for determining the bearing capacities of unconfined bolted connections.
    publisherASCE
    titleUltimate Bearing Capacity of Unconfined Bolted Connections in Cold-Formed Steel Members
    typeJournal Paper
    journal volume147
    journal issue5
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002992
    journal fristpage04021048-1
    journal lastpage04021048-10
    page10
    treeJournal of Structural Engineering:;2021:;Volume ( 147 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian