    Eccentric-Axial-Load Test for Composite Columns Using Bolt-Connected Steel Angles

    Source: Journal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 009
    Author:
    Hyeon-Jin Kim
    ,
    Hyeon-Jong Hwang
    ,
    Hong-Gun Park
    DOI: 10.1061/(ASCE)ST.1943-541X.0002699
    Publisher: ASCE
    Abstract: For better structural performance and constructability, a concrete-encased steel column that uses a steel cage prefabricated with bolt connections was developed. The steel cage consists of longitudinal steel angles and transverse steel plates. As a fundamental verification of the proposed column, an eccentric-axial-load test was performed on eight composite column specimens. Test parameters included column type (i.e., conventional concrete-encased steel column versus proposed column), shape and spacing of transverse plate, and axial load eccentricity. The test results showed that, owing to the high flexural stiffness of the steel angles placed at the corners of the cross section, the axial strength and ductility of the proposed column were greater than those of the conventional composite column using a wide flange steel section at the center of the cross section, particularly in the large eccentricity of axial load. Z-section plates and closely spaced flat plates used for transverse reinforcement provided better lateral confinement to the concrete, thereby increasing the load-carrying capacity of the proposed columns. In general, existing design methods safely predicted the axial-flexural capacities of the specimens. Nonlinear numerical analysis was performed to verify test results. The numerical analysis results agreed with the test results in terms of yield stiffness, peak strength, and postpeak strength degradation.
    • Download: (4.863Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Eccentric-Axial-Load Test for Composite Columns Using Bolt-Connected Steel Angles

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4267608
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorHyeon-Jin Kim
    contributor authorHyeon-Jong Hwang
    contributor authorHong-Gun Park
    date accessioned2022-01-30T21:04:25Z
    date available2022-01-30T21:04:25Z
    date issued9/1/2020 12:00:00 AM
    identifier other%28ASCE%29ST.1943-541X.0002699.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267608
    description abstractFor better structural performance and constructability, a concrete-encased steel column that uses a steel cage prefabricated with bolt connections was developed. The steel cage consists of longitudinal steel angles and transverse steel plates. As a fundamental verification of the proposed column, an eccentric-axial-load test was performed on eight composite column specimens. Test parameters included column type (i.e., conventional concrete-encased steel column versus proposed column), shape and spacing of transverse plate, and axial load eccentricity. The test results showed that, owing to the high flexural stiffness of the steel angles placed at the corners of the cross section, the axial strength and ductility of the proposed column were greater than those of the conventional composite column using a wide flange steel section at the center of the cross section, particularly in the large eccentricity of axial load. Z-section plates and closely spaced flat plates used for transverse reinforcement provided better lateral confinement to the concrete, thereby increasing the load-carrying capacity of the proposed columns. In general, existing design methods safely predicted the axial-flexural capacities of the specimens. Nonlinear numerical analysis was performed to verify test results. The numerical analysis results agreed with the test results in terms of yield stiffness, peak strength, and postpeak strength degradation.
    publisherASCE
    titleEccentric-Axial-Load Test for Composite Columns Using Bolt-Connected Steel Angles
    typeJournal Paper
    journal volume146
    journal issue9
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002699
    page14
    treeJournal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian