YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Monitoring of a Tall Building Equipped with an Efficient Multiple-Tuned Sloshing Damper System

    Source: Practice Periodical on Structural Design and Construction:;2020:;Volume ( 025 ):;issue: 003
    Author:
    J. S. Love
    ,
    B. Morava
    ,
    A. W. Smith
    DOI: 10.1061/(ASCE)SC.1943-5576.0000481
    Publisher: ASCE
    Abstract: An efficient multiple tuned sloshing damper (MTSD) system is installed in a tall building in Toronto, Canada. The building is monitored before and after water is added to the tanks to measure wind-induced building motion, and evaluate the performance of the MTSD. To the authors’ knowledge, this is the first time an MTSD system has been installed in a tall building, and one of the few times the as-built performance of a tall building supplementary damping system has been evaluated and reported in the literature. Monitoring of the building motion before commissioning the MTSD indicated that the structural frequencies were very close to those originally predicted by the structural engineer’s finite element model. Only 0.8% inherent structural damping was measured for the first mode when the peak building acceleration was 7 milli-g. The measured and wind tunnel predicted wind-induced building accelerations are in good agreement. After commissioning the MTSD system, the measured building accelerations and MTSD wave heights are found to be well-aligned with predictions. Several techniques are used to evaluate the performance of the MTSD system using the measured data. Each technique confirms that the MTSD system reduced building accelerations by approximately 50%. Full-scale structural monitoring has therefore shown that MTSDs can significantly reduce the motion of tall buildings.
    • Download: (4.481Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Monitoring of a Tall Building Equipped with an Efficient Multiple-Tuned Sloshing Damper System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4267525
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorJ. S. Love
    contributor authorB. Morava
    contributor authorA. W. Smith
    date accessioned2022-01-30T21:01:36Z
    date available2022-01-30T21:01:36Z
    date issued8/1/2020 12:00:00 AM
    identifier other%28ASCE%29SC.1943-5576.0000481.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4267525
    description abstractAn efficient multiple tuned sloshing damper (MTSD) system is installed in a tall building in Toronto, Canada. The building is monitored before and after water is added to the tanks to measure wind-induced building motion, and evaluate the performance of the MTSD. To the authors’ knowledge, this is the first time an MTSD system has been installed in a tall building, and one of the few times the as-built performance of a tall building supplementary damping system has been evaluated and reported in the literature. Monitoring of the building motion before commissioning the MTSD indicated that the structural frequencies were very close to those originally predicted by the structural engineer’s finite element model. Only 0.8% inherent structural damping was measured for the first mode when the peak building acceleration was 7 milli-g. The measured and wind tunnel predicted wind-induced building accelerations are in good agreement. After commissioning the MTSD system, the measured building accelerations and MTSD wave heights are found to be well-aligned with predictions. Several techniques are used to evaluate the performance of the MTSD system using the measured data. Each technique confirms that the MTSD system reduced building accelerations by approximately 50%. Full-scale structural monitoring has therefore shown that MTSDs can significantly reduce the motion of tall buildings.
    publisherASCE
    titleMonitoring of a Tall Building Equipped with an Efficient Multiple-Tuned Sloshing Damper System
    typeJournal Paper
    journal volume25
    journal issue3
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)SC.1943-5576.0000481
    page11
    treePractice Periodical on Structural Design and Construction:;2020:;Volume ( 025 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian