    Effects of End Distance and Temperature on Thin-Sheet Steel Double Shear-Bolted Connections

    Source: Journal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 007
    Author:
    Yancheng Cai
    ,
    Ben Young
    DOI: 10.1061/(ASCE)ST.1943-541X.0002664
    Publisher: ASCE
    Abstract: An experimental investigation was conducted with thin-sheet steel (TSS) double shear-bolted connections at elevated temperatures. The connection specimens were fabricated by TSS 0.42-mm G550 and 1.90-mm G450. The specimens were designed with variation in end distance. The tests were conducted at five different nominal temperature levels up to 900°C using the steady-state test method. The variation of the end distance and temperature on the behavior of the connection specimens was investigated. The increment of the connection ultimate load was found as the end distance increased up to five times the diameter of the bolt. It was also found that deteriorations of connection strengths occurred in a similar manner to the corresponding material properties at elevated temperatures. At each nominal temperature level, as the end distance increased, the failure modes of specimens changed from tearout to bearing. The experimental results were compared with predictions by using international design codes for cold-formed steel structures, including NAS 2016, EC3-1.3, and AS/NZS 2018. In calculating the nominal strengths of the connections, the reduced material properties of TSS obtained at elevated temperatures were used. Overall, the predictions from NAS, EC3-1.3, and AS/NZS were found to be conservative, with AS/NZS providing the least conservative and least scattered predictions. In general, NAS and AS/NZS could accurately predict the failure modes for TSS connection specimens that failed in tearout and bearing failure at different temperature levels.
    • Download: (1.924Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effects of End Distance and Temperature on Thin-Sheet Steel Double Shear-Bolted Connections

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266704
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorYancheng Cai
    contributor authorBen Young
    date accessioned2022-01-30T20:13:05Z
    date available2022-01-30T20:13:05Z
    date issued2020
    identifier other%28ASCE%29ST.1943-541X.0002664.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266704
    description abstractAn experimental investigation was conducted with thin-sheet steel (TSS) double shear-bolted connections at elevated temperatures. The connection specimens were fabricated by TSS 0.42-mm G550 and 1.90-mm G450. The specimens were designed with variation in end distance. The tests were conducted at five different nominal temperature levels up to 900°C using the steady-state test method. The variation of the end distance and temperature on the behavior of the connection specimens was investigated. The increment of the connection ultimate load was found as the end distance increased up to five times the diameter of the bolt. It was also found that deteriorations of connection strengths occurred in a similar manner to the corresponding material properties at elevated temperatures. At each nominal temperature level, as the end distance increased, the failure modes of specimens changed from tearout to bearing. The experimental results were compared with predictions by using international design codes for cold-formed steel structures, including NAS 2016, EC3-1.3, and AS/NZS 2018. In calculating the nominal strengths of the connections, the reduced material properties of TSS obtained at elevated temperatures were used. Overall, the predictions from NAS, EC3-1.3, and AS/NZS were found to be conservative, with AS/NZS providing the least conservative and least scattered predictions. In general, NAS and AS/NZS could accurately predict the failure modes for TSS connection specimens that failed in tearout and bearing failure at different temperature levels.
    publisherASCE
    titleEffects of End Distance and Temperature on Thin-Sheet Steel Double Shear-Bolted Connections
    typeJournal Paper
    journal volume146
    journal issue7
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002664
    page04020120
    treeJournal of Structural Engineering:;2020:;Volume ( 146 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian