    Performance and Durability of In-Plant Partially Cured GFRP Bent Bars in Steam-Cured Precast Concrete Elements

    Source: Journal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 004
    Author:
    Brahim Benmokrane
    ,
    Khaled Mohamed
    ,
    Patrice Cousin
    DOI: 10.1061/(ASCE)CC.1943-5614.0001028
    Publisher: ASCE
    Abstract: Glass fiber-reinforced polymer (GFRP) bent bars were used as shear reinforcement for precast/prestressed concrete box beams in Ontario, Canada. Differential scanning calorimetry (DSC) tests performed on the bent GFRP bars revealed a curing ratio varying from 88% to 94% and a glass transition temperature ranging from 63°C to 71°C (lower than the limits of 95% and 100°C, respectively, specified in the CSA S807 FRP-material specifications). This study investigated the consequence of implementing partially cured GFRP bars in constructing steam-cured precast-prestressed concrete bridge box beams. The physical and mechanical properties of the partially cured GFRP bars were evaluated and compared with the properties of GFRP bars postheated at 80°C for 4 h. The durability performance was also assessed by immersing the GFRP bars in alkaline solution at 70°C for 2,200 and 4,300 h. Moreover, scanning electron microscopy (SEM) observations were performed to assess the microstructure of the GFRP bars. The results show that the glass transition temperature, Tg, and interlaminar shear strength were the criteria most affected by the degree of curing. Exposing the bars to steam treatment (as is the case for precast concrete box beams) increased the cure ratio and, consequently, the Tg and interlaminar shear strength of the bars. This was verified by simulating the concrete mix design used in the precast concrete process [including the same water-to-cement ratio (w/c) and aggregate type] and exposing the concrete to the same steam-treatment conditions. The steam treatment promoted the postpolymerization of the GFRP bars, leading to a cure ratio of 98%, which exceeds the limit specified in CSA S807 and enhanced bar properties. The results of this study have been instrumental in developing the new edition of CSA S807 standard incorporating evaluation of the physical, durability, and mechanical properties of bent FRP bars. Moreover, the reported study constitutes a valuable contribution to the state-of-the-practice.
    • Download: (1.684Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Performance and Durability of In-Plant Partially Cured GFRP Bent Bars in Steam-Cured Precast Concrete Elements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266651
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorBrahim Benmokrane
    contributor authorKhaled Mohamed
    contributor authorPatrice Cousin
    date accessioned2022-01-30T20:11:09Z
    date available2022-01-30T20:11:09Z
    date issued2020
    identifier other%28ASCE%29CC.1943-5614.0001028.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266651
    description abstractGlass fiber-reinforced polymer (GFRP) bent bars were used as shear reinforcement for precast/prestressed concrete box beams in Ontario, Canada. Differential scanning calorimetry (DSC) tests performed on the bent GFRP bars revealed a curing ratio varying from 88% to 94% and a glass transition temperature ranging from 63°C to 71°C (lower than the limits of 95% and 100°C, respectively, specified in the CSA S807 FRP-material specifications). This study investigated the consequence of implementing partially cured GFRP bars in constructing steam-cured precast-prestressed concrete bridge box beams. The physical and mechanical properties of the partially cured GFRP bars were evaluated and compared with the properties of GFRP bars postheated at 80°C for 4 h. The durability performance was also assessed by immersing the GFRP bars in alkaline solution at 70°C for 2,200 and 4,300 h. Moreover, scanning electron microscopy (SEM) observations were performed to assess the microstructure of the GFRP bars. The results show that the glass transition temperature, Tg, and interlaminar shear strength were the criteria most affected by the degree of curing. Exposing the bars to steam treatment (as is the case for precast concrete box beams) increased the cure ratio and, consequently, the Tg and interlaminar shear strength of the bars. This was verified by simulating the concrete mix design used in the precast concrete process [including the same water-to-cement ratio (w/c) and aggregate type] and exposing the concrete to the same steam-treatment conditions. The steam treatment promoted the postpolymerization of the GFRP bars, leading to a cure ratio of 98%, which exceeds the limit specified in CSA S807 and enhanced bar properties. The results of this study have been instrumental in developing the new edition of CSA S807 standard incorporating evaluation of the physical, durability, and mechanical properties of bent FRP bars. Moreover, the reported study constitutes a valuable contribution to the state-of-the-practice.
    publisherASCE
    titlePerformance and Durability of In-Plant Partially Cured GFRP Bent Bars in Steam-Cured Precast Concrete Elements
    typeJournal Paper
    journal volume24
    journal issue4
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0001028
    page04020020
    treeJournal of Composites for Construction:;2020:;Volume ( 024 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian