    Optimal Pipe Sizing and Operation of Multistage Centrifugal Pumps for Water Supply

    Source: Journal of Pipeline Systems Engineering and Practice:;2020:;Volume ( 011 ):;issue: 002
    Author:
    Sonam Pandey
    ,
    R. P. Singh
    ,
    P. S. Mahar
    DOI: 10.1061/(ASCE)PS.1949-1204.0000447
    Publisher: ASCE
    Abstract: The operation of multistage pumps transporting water from the source to the delivery point requires balancing of the pressure at the junction of the pump and pipeline according to their characteristics. In this paper, nonlinear optimization models are developed to minimize the total annual cost for selecting the sizes of the pipelines in series and parallel connections of pumps taking water from one or more sources. The models are based on life cycle cost analysis, including replacement cost and escalating energy cost factors. The combined characteristic equations of the pumps in series and parallel connections are obtained using the characteristic equation of a single-stage pump. The constraints are imposed for the pressures at the junctions of the pipeline, with the pumps having different characteristics especially drawing water from different sources. The discharges of the pumps are regulated automatically according to the pressures adjusted at the junctions due to the resistance developed by the optimally designed pipe sizes. The requirements of the desired efficiency also are considered constraints in the models. The applicability of the developed models is illustrated through design examples to obtain optimal discharge and pipe sizes from a single water source for series and parallel connections. Also, the examples are solved to obtain the optimal pipe sizes and discharges from different pumps with the same and different characteristics and drawing water from multiple sources.
    • Download: (927.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Optimal Pipe Sizing and Operation of Multistage Centrifugal Pumps for Water Supply

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4266446
    Collections
    • Journal of Pipeline Systems Engineering and Practice

    Show full item record

    contributor authorSonam Pandey
    contributor authorR. P. Singh
    contributor authorP. S. Mahar
    date accessioned2022-01-30T20:03:38Z
    date available2022-01-30T20:03:38Z
    date issued2020
    identifier other%28ASCE%29PS.1949-1204.0000447.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4266446
    description abstractThe operation of multistage pumps transporting water from the source to the delivery point requires balancing of the pressure at the junction of the pump and pipeline according to their characteristics. In this paper, nonlinear optimization models are developed to minimize the total annual cost for selecting the sizes of the pipelines in series and parallel connections of pumps taking water from one or more sources. The models are based on life cycle cost analysis, including replacement cost and escalating energy cost factors. The combined characteristic equations of the pumps in series and parallel connections are obtained using the characteristic equation of a single-stage pump. The constraints are imposed for the pressures at the junctions of the pipeline, with the pumps having different characteristics especially drawing water from different sources. The discharges of the pumps are regulated automatically according to the pressures adjusted at the junctions due to the resistance developed by the optimally designed pipe sizes. The requirements of the desired efficiency also are considered constraints in the models. The applicability of the developed models is illustrated through design examples to obtain optimal discharge and pipe sizes from a single water source for series and parallel connections. Also, the examples are solved to obtain the optimal pipe sizes and discharges from different pumps with the same and different characteristics and drawing water from multiple sources.
    publisherASCE
    titleOptimal Pipe Sizing and Operation of Multistage Centrifugal Pumps for Water Supply
    typeJournal Paper
    journal volume11
    journal issue2
    journal titleJournal of Pipeline Systems Engineering and Practice
    identifier doi10.1061/(ASCE)PS.1949-1204.0000447
    page04020007
    treeJournal of Pipeline Systems Engineering and Practice:;2020:;Volume ( 011 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian