    Effect of Using a Ceramic Separator on the Performance of Hydroponic Constructed Wetland-Microbial Fuel Cell

    Source: Journal of Hazardous, Toxic, and Radioactive Waste:;2020:;Volume ( 024 ):;issue: 003
    Author:
    Chabungbam Niranjit Khuman
    ,
    Gourav Dhar Bhowmick
    ,
    Makarand M. Ghangrekar
    ,
    Arunabha Mitra
    DOI: 10.1061/(ASCE)HZ.2153-5515.0000499
    Publisher: ASCE
    Abstract: Lack of proper physical separation between the anodic and cathodic zones of a constructed wetland-microbial fuel cell (CW-MFC) causes higher oxygen diffusion into the anodic zone, which leads to nonproductive electron losses. In this investigation, performance of two upflow hydroponic CW-MFCs with a low-cost ceramic separator (R1) and without a separator (R2) was evaluated with Canna indica at the cathodic side. The chemical oxygen demand removal efficiencies of R1 and R2 were found to be 86.2 ± 8.1% and 91.5 ± 4.9%, respectively. However, from the polarization plots, internal resistance of R1 (240 Ω) was found to be 2.6 times lower than that of R2 (626 Ω). In addition, it was revealed that R1 (258.78 mW·m−3) exhibited almost three times higher power density than R2 (91.02 mW·m−3). The normalized energy recovery of the CW-MFC with a ceramic separator was also 2.7 times higher than that without a separator. The presence of a separator thus facilitated better anaerobicity to support substrate utilization by electrogenesis in the anodic zone of R1 and prevented oxygen diffusion, which resulted in higher energy recovery while only marginally compromising the efficiency of organic matter removal.
    • Download: (645.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effect of Using a Ceramic Separator on the Performance of Hydroponic Constructed Wetland-Microbial Fuel Cell

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4265687
    Collections
    • Journal of Hazardous, Toxic, and Radioactive Waste

    Show full item record

    contributor authorChabungbam Niranjit Khuman
    contributor authorGourav Dhar Bhowmick
    contributor authorMakarand M. Ghangrekar
    contributor authorArunabha Mitra
    date accessioned2022-01-30T19:38:02Z
    date available2022-01-30T19:38:02Z
    date issued2020
    identifier other%28ASCE%29HZ.2153-5515.0000499.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4265687
    description abstractLack of proper physical separation between the anodic and cathodic zones of a constructed wetland-microbial fuel cell (CW-MFC) causes higher oxygen diffusion into the anodic zone, which leads to nonproductive electron losses. In this investigation, performance of two upflow hydroponic CW-MFCs with a low-cost ceramic separator (R1) and without a separator (R2) was evaluated with Canna indica at the cathodic side. The chemical oxygen demand removal efficiencies of R1 and R2 were found to be 86.2 ± 8.1% and 91.5 ± 4.9%, respectively. However, from the polarization plots, internal resistance of R1 (240 Ω) was found to be 2.6 times lower than that of R2 (626 Ω). In addition, it was revealed that R1 (258.78 mW·m−3) exhibited almost three times higher power density than R2 (91.02 mW·m−3). The normalized energy recovery of the CW-MFC with a ceramic separator was also 2.7 times higher than that without a separator. The presence of a separator thus facilitated better anaerobicity to support substrate utilization by electrogenesis in the anodic zone of R1 and prevented oxygen diffusion, which resulted in higher energy recovery while only marginally compromising the efficiency of organic matter removal.
    publisherASCE
    titleEffect of Using a Ceramic Separator on the Performance of Hydroponic Constructed Wetland-Microbial Fuel Cell
    typeJournal Paper
    journal volume24
    journal issue3
    journal titleJournal of Hazardous, Toxic, and Radioactive Waste
    identifier doi10.1061/(ASCE)HZ.2153-5515.0000499
    page04020005
    treeJournal of Hazardous, Toxic, and Radioactive Waste:;2020:;Volume ( 024 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian