    Air-Handling-Unit Discharge Air Temperature Reset Based on Outdoor Air Temperature and Cooling Energy Performance in an Office Building

    Source: Journal of Energy Engineering:;2020:;Volume ( 146 ):;issue: 003
    Author:
    Min-Kyeong Park
    ,
    Jong-Man Lee
    ,
    Won-Hee Kang
    ,
    Chul-Ho Kim
    ,
    Kwang Ho Lee
    DOI: 10.1061/(ASCE)EY.1943-7897.0000660
    Publisher: ASCE
    Abstract: In many office buildings, an air-handling unit (AHU) in a variable air volume (VAV) system is operated using discharge air temperature (DAT) simply fixed at a particular set point. However, this simply fixed control causes a variety of inefficiencies related to cooling energy. Therefore, this study compares the cooling energy consumption of the fixed-control strategy, which fixes the AHU DAT at a specific temperature, and the cooling energy consumption of an AHU DAT set point reset strategy based on the outdoor air (OA) temperature, which proportionally controls the AHU DAT according to the change of the OA temperature. Commercially available software was used to compare the AHU DAT control methods of fixed control and the AHU DAT set point reset strategies. The comparison results show that the effect of reducing the total cooling energy consumption in summer (June to August) is negligible; however, in spring (March to May) and autumn (September to November), it was found to be significant compared with the single-fixed-control method. Therefore, if a method of proportionally controlling the AHU DAT is implemented, as in the case of the AHU DAT set point reset based on the OA temperature, it could be an advanced control scheme to improve energy efficiency, especially by reducing the energy consumption of the chiller, which accounts for the highest proportion of the total cooling energy consumption.
    • Download: (1.858Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Air-Handling-Unit Discharge Air Temperature Reset Based on Outdoor Air Temperature and Cooling Energy Performance in an Office Building

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4265555
    Collections
    • Journal of Energy Engineering

    Show full item record

    contributor authorMin-Kyeong Park
    contributor authorJong-Man Lee
    contributor authorWon-Hee Kang
    contributor authorChul-Ho Kim
    contributor authorKwang Ho Lee
    date accessioned2022-01-30T19:33:59Z
    date available2022-01-30T19:33:59Z
    date issued2020
    identifier other%28ASCE%29EY.1943-7897.0000660.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4265555
    description abstractIn many office buildings, an air-handling unit (AHU) in a variable air volume (VAV) system is operated using discharge air temperature (DAT) simply fixed at a particular set point. However, this simply fixed control causes a variety of inefficiencies related to cooling energy. Therefore, this study compares the cooling energy consumption of the fixed-control strategy, which fixes the AHU DAT at a specific temperature, and the cooling energy consumption of an AHU DAT set point reset strategy based on the outdoor air (OA) temperature, which proportionally controls the AHU DAT according to the change of the OA temperature. Commercially available software was used to compare the AHU DAT control methods of fixed control and the AHU DAT set point reset strategies. The comparison results show that the effect of reducing the total cooling energy consumption in summer (June to August) is negligible; however, in spring (March to May) and autumn (September to November), it was found to be significant compared with the single-fixed-control method. Therefore, if a method of proportionally controlling the AHU DAT is implemented, as in the case of the AHU DAT set point reset based on the OA temperature, it could be an advanced control scheme to improve energy efficiency, especially by reducing the energy consumption of the chiller, which accounts for the highest proportion of the total cooling energy consumption.
    publisherASCE
    titleAir-Handling-Unit Discharge Air Temperature Reset Based on Outdoor Air Temperature and Cooling Energy Performance in an Office Building
    typeJournal Paper
    journal volume146
    journal issue3
    journal titleJournal of Energy Engineering
    identifier doi10.1061/(ASCE)EY.1943-7897.0000660
    page04020013
    treeJournal of Energy Engineering:;2020:;Volume ( 146 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian