    Archive

    A Multiple Linear Regression Algorithm for Sea Surface Temperature Retrieval by One-Dimensional Synthetic Aperture Microwave Radiometry

    Source: Journal of Atmospheric and Oceanic Technology:;2020:;volume( 37 ):;issue: 009::page 1753
    Author:
    Feng, Mengyan;Ai, Weihua;Chen, Guanyu;Lu, Wen;Ma, Shuo
    DOI: 10.1175/JTECH-D-20-0003.1
    Publisher: American Meteorological Society
    Abstract: One-dimensional synthetic aperture microwave radiometer (1D-SAMR) can provide remote sensing images at a higher spatial resolution than those from traditional real aperture microwave radiometers. As 1D-SAMR operates at multiple incidence angles, we proposed a multiple linear regression method to retrieve sea surface temperature at an incidence angle between 0° and 65°. Assuming that a 1D-SAMR operates at various frequencies (i.e., 6.9, 10.65, 18.7, 23.8 and 36.5 GHz), a radiation transmission forward model was developed to simulate the brightness temperature measured by the 1D-SAMR. The sensitivity of the five frequencies to sea surface temperature was examined, and we evaluated the reliability of the regression method proposed in this study. Furthermore, 11 schemes with various frequency combinations were applied to retrieve sea surface temperature. The results showed that the five-frequency combination scheme performed better than the other schemes. This study also found that the accuracy of retrieved sea surface temperature is dependent on incidence angles. Finally, we suggested that the incidence angle range of the 1D-SAMR is necessary to be 30°–60° based on the relationship between the accuracy of retrieved sea surface temperature and the incidence angles.
    • Download: (1.308Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Multiple Linear Regression Algorithm for Sea Surface Temperature Retrieval by One-Dimensional Synthetic Aperture Microwave Radiometry

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4264572
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorFeng, Mengyan;Ai, Weihua;Chen, Guanyu;Lu, Wen;Ma, Shuo
    date accessioned2022-01-30T18:09:04Z
    date available2022-01-30T18:09:04Z
    date copyright9/17/2020 12:00:00 AM
    date issued2020
    identifier issn0739-0572
    identifier otherjtechd200003.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4264572
    description abstractOne-dimensional synthetic aperture microwave radiometer (1D-SAMR) can provide remote sensing images at a higher spatial resolution than those from traditional real aperture microwave radiometers. As 1D-SAMR operates at multiple incidence angles, we proposed a multiple linear regression method to retrieve sea surface temperature at an incidence angle between 0° and 65°. Assuming that a 1D-SAMR operates at various frequencies (i.e., 6.9, 10.65, 18.7, 23.8 and 36.5 GHz), a radiation transmission forward model was developed to simulate the brightness temperature measured by the 1D-SAMR. The sensitivity of the five frequencies to sea surface temperature was examined, and we evaluated the reliability of the regression method proposed in this study. Furthermore, 11 schemes with various frequency combinations were applied to retrieve sea surface temperature. The results showed that the five-frequency combination scheme performed better than the other schemes. This study also found that the accuracy of retrieved sea surface temperature is dependent on incidence angles. Finally, we suggested that the incidence angle range of the 1D-SAMR is necessary to be 30°–60° based on the relationship between the accuracy of retrieved sea surface temperature and the incidence angles.
    publisherAmerican Meteorological Society
    titleA Multiple Linear Regression Algorithm for Sea Surface Temperature Retrieval by One-Dimensional Synthetic Aperture Microwave Radiometry
    typeJournal Paper
    journal volume37
    journal issue9
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH-D-20-0003.1
    journal fristpage1753
    journal lastpage1761
    treeJournal of Atmospheric and Oceanic Technology:;2020:;volume( 37 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian