    Numerical and Experimental Investigation on the Function of Siphons for Tipping-Bucket Rain Gauges

    Source: Journal of Atmospheric and Oceanic Technology:;2020:;volume( 37 ):;issue: 007::page 1189
    Author:
    Cai, Zhao;Liu, Jiufu;Liao, Aimin;Li, Xuegang;Liao, Minhan
    DOI: 10.1175/JTECH-D-19-0166.1
    Publisher: American Meteorological Society
    Abstract: Siphons can effectively reduce the influence of rainfall intensity on the mechanical bias of tipping-bucket rain gauges (TBRs). To identify the function of siphons for TBRs, this study investigated three types of siphons: a Texas Electronics (TE) siphon, a RIMCO (RIM) siphon, and a Sutron siphon, with both computational fluid dynamics (CFD) simulations and laboratory experiments. To provide better structural designs, further simulations were conducted to adjust two parameters of the siphons: d, the distance from the cap to the outer part, and w, the distance from the main part to the cap part. The simulation results reveal that the most significant advantage of a siphon over a rain gauge collector is to provide stable outflow for the tipping bucket. The stable outflow rates were around 1.5 g s−1 (TE) and 1.55 g s−1 (RIM), while the Sutron siphon increased from 1.75 to 2.45 g s−1. The ratio of stable outflow time to a complete siphon event was 69% (TE), 81% (Sutron), and 83% (RIM). In experiments with rainfall intensity higher than 1 mm min−1, the RIM and TE siphons showed oscillations in the outflow during consecutive siphon events, whereas the Sutron siphon was relatively stable. Further simulations showed that the recommended d and w for the TE siphon are 2.5 and 1.1 mm, respectively, while the recommendations for the RIM siphon are d = 2.5 mm and w = 0.9 mm. The manufacturer’s specifications for d and w are best for the Sutron siphon. These results help to understand the functionality of siphons for TBRs, and benefit the structural design of common siphons.
    • Download: (2.503Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Numerical and Experimental Investigation on the Function of Siphons for Tipping-Bucket Rain Gauges

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4264549
    Collections
    • Journal of Atmospheric and Oceanic Technology

    Show full item record

    contributor authorCai, Zhao;Liu, Jiufu;Liao, Aimin;Li, Xuegang;Liao, Minhan
    date accessioned2022-01-30T18:08:14Z
    date available2022-01-30T18:08:14Z
    date copyright7/6/2020 12:00:00 AM
    date issued2020
    identifier issn0739-0572
    identifier otherjtechd190166.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4264549
    description abstractSiphons can effectively reduce the influence of rainfall intensity on the mechanical bias of tipping-bucket rain gauges (TBRs). To identify the function of siphons for TBRs, this study investigated three types of siphons: a Texas Electronics (TE) siphon, a RIMCO (RIM) siphon, and a Sutron siphon, with both computational fluid dynamics (CFD) simulations and laboratory experiments. To provide better structural designs, further simulations were conducted to adjust two parameters of the siphons: d, the distance from the cap to the outer part, and w, the distance from the main part to the cap part. The simulation results reveal that the most significant advantage of a siphon over a rain gauge collector is to provide stable outflow for the tipping bucket. The stable outflow rates were around 1.5 g s−1 (TE) and 1.55 g s−1 (RIM), while the Sutron siphon increased from 1.75 to 2.45 g s−1. The ratio of stable outflow time to a complete siphon event was 69% (TE), 81% (Sutron), and 83% (RIM). In experiments with rainfall intensity higher than 1 mm min−1, the RIM and TE siphons showed oscillations in the outflow during consecutive siphon events, whereas the Sutron siphon was relatively stable. Further simulations showed that the recommended d and w for the TE siphon are 2.5 and 1.1 mm, respectively, while the recommendations for the RIM siphon are d = 2.5 mm and w = 0.9 mm. The manufacturer’s specifications for d and w are best for the Sutron siphon. These results help to understand the functionality of siphons for TBRs, and benefit the structural design of common siphons.
    publisherAmerican Meteorological Society
    titleNumerical and Experimental Investigation on the Function of Siphons for Tipping-Bucket Rain Gauges
    typeJournal Paper
    journal volume37
    journal issue7
    journal titleJournal of Atmospheric and Oceanic Technology
    identifier doi10.1175/JTECH-D-19-0166.1
    journal fristpage1189
    journal lastpage1201
    treeJournal of Atmospheric and Oceanic Technology:;2020:;volume( 37 ):;issue: 007
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian