Show simple item record

contributor authorTony M. Allen
contributor authorRichard J. Bathurst
contributor authorNezam Bozorgzadeh
date accessioned2019-09-18T10:42:55Z
date available2019-09-18T10:42:55Z
date issued2019
identifier other%28ASCE%29GT.1943-5606.0002043.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4260626
description abstractDesign for the tensile strength limit state of steel strip reinforcement in mechanically stabilized earth (MSE) walls must provide for loss of steel thickness due to corrosion. The paper combined key features of zinc and steel corrosion models found in the literature with corrosion rate statistics for buried galvanized steel strips. Examples of loss of strength of reinforcement strips of different thickness for up to 120 years after construction were presented in probabilistic terms. Results of probabilistic analysis for the tensile strength limit state at a design life of 75 years were demonstrated for a typical wall using three different models to compute the maximum tensile load in a strip under operational conditions. The same three models were used to demonstrate a methodology for load and resistance factor design (LRFD) calibration for the tensile strength limit state for steel reinforcement strips. The calculations showed that the accuracy of the load model with respect to measured loads has a strong influence on the magnitude of computed resistance factor for a prescribed load factor and maximum target level of reliability.
publisherAmerican Society of Civil Engineers
titleProbabilistic Tensile Strength Analysis of Steel Strips in MSE Walls Considering Corrosion
typeJournal Paper
journal volume145
journal issue5
journal titleJournal of Geotechnical and Geoenvironmental Engineering
identifier doi10.1061/(ASCE)GT.1943-5606.0002043
page04019016
treeJournal of Geotechnical and Geoenvironmental Engineering:;2019:;Volume ( 145 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record