    Effect of Interface Friction Angle between Soil and Reinforcement on Bearing Capacity of Strip Footing Placed on Reinforced Slope

    Source: International Journal of Geomechanics:;2019:;Volume ( 019 ):;issue: 005
    Author:
    Koushik Halder
    ,
    Debarghya Chakraborty
    DOI: 10.1061/(ASCE)GM.1943-5622.0001394
    Publisher: American Society of Civil Engineers
    Abstract: In the last few decades, many experimental and a few numerical investigations were performed to investigate the behavior of strip footing placed on the soil slope. However, most of the previous studies were case specific. Thus, due to the nonavailability of the design charts for the computation of the bearing capacity of strip footing placed on the edge of the slope reinforced with more than one layer of reinforcement, the authors were impelled to conduct the present study. The effect of the interface friction angle between soil and reinforcement, which seems to have a significant effect on the bearing capacity of strip footing, also is not considered in the previous studies. By using the lower bound finite-element limit analysis technique, a set of design charts are prepared to compute the bearing capacity of a strip footing placed on the top of a cohesionless soil slope reinforced with two layers of reinforcement. The effect of (1) slope angle (β), (2) soil friction angle (ϕ), (3) depth of the first layer of reinforcement from the footing base (d1/B), (4) depth of the second layer of reinforcement (d2/B) from the first layer of reinforcement, and (5) interface friction angle between cohesionless soil and reinforcement layer (δ) are considered during the analysis. As expected, with the addition of a reinforcement layer, the bearing capacity increases. The efficacy of the reinforcement layer is quantified in terms of ηγ, which is the ratio between the Nγ values obtained for the reinforced and unreinforced slopes. The value of efficiency factor increases up to a certain value of d1/B for a single layer of reinforcement and d1/B and d2/B for a double layer of reinforcement; after that it reduces. Because of the reduction in the magnitude of δ for single and double reinforced slopes, the effectiveness of the reinforcement decreases. The axial tension (T) generated due to the friction between the moving soil particles and reinforcement is also plotted throughout the reinforcement layer. One can easily compute the optimum length (Lopt) of the reinforcement required to avert tensile failure from these graphs. The effect of soil dilatancy on the bearing capacity of strip footing placed on the double reinforced slope is investigated for a number of cases. Failure patterns are also plotted for a better understanding of the failure mechanisms of strip footing placed on the edge of the reinforced cohesionless soil slope.
    • Download: (2.322Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Effect of Interface Friction Angle between Soil and Reinforcement on Bearing Capacity of Strip Footing Placed on Reinforced Slope

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4260216
    Collections
    • International Journal of Geomechanics

    Show full item record

    contributor authorKoushik Halder
    contributor authorDebarghya Chakraborty
    date accessioned2019-09-18T10:40:56Z
    date available2019-09-18T10:40:56Z
    date issued2019
    identifier other%28ASCE%29GM.1943-5622.0001394.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4260216
    description abstractIn the last few decades, many experimental and a few numerical investigations were performed to investigate the behavior of strip footing placed on the soil slope. However, most of the previous studies were case specific. Thus, due to the nonavailability of the design charts for the computation of the bearing capacity of strip footing placed on the edge of the slope reinforced with more than one layer of reinforcement, the authors were impelled to conduct the present study. The effect of the interface friction angle between soil and reinforcement, which seems to have a significant effect on the bearing capacity of strip footing, also is not considered in the previous studies. By using the lower bound finite-element limit analysis technique, a set of design charts are prepared to compute the bearing capacity of a strip footing placed on the top of a cohesionless soil slope reinforced with two layers of reinforcement. The effect of (1) slope angle (β), (2) soil friction angle (ϕ), (3) depth of the first layer of reinforcement from the footing base (d1/B), (4) depth of the second layer of reinforcement (d2/B) from the first layer of reinforcement, and (5) interface friction angle between cohesionless soil and reinforcement layer (δ) are considered during the analysis. As expected, with the addition of a reinforcement layer, the bearing capacity increases. The efficacy of the reinforcement layer is quantified in terms of ηγ, which is the ratio between the Nγ values obtained for the reinforced and unreinforced slopes. The value of efficiency factor increases up to a certain value of d1/B for a single layer of reinforcement and d1/B and d2/B for a double layer of reinforcement; after that it reduces. Because of the reduction in the magnitude of δ for single and double reinforced slopes, the effectiveness of the reinforcement decreases. The axial tension (T) generated due to the friction between the moving soil particles and reinforcement is also plotted throughout the reinforcement layer. One can easily compute the optimum length (Lopt) of the reinforcement required to avert tensile failure from these graphs. The effect of soil dilatancy on the bearing capacity of strip footing placed on the double reinforced slope is investigated for a number of cases. Failure patterns are also plotted for a better understanding of the failure mechanisms of strip footing placed on the edge of the reinforced cohesionless soil slope.
    publisherAmerican Society of Civil Engineers
    titleEffect of Interface Friction Angle between Soil and Reinforcement on Bearing Capacity of Strip Footing Placed on Reinforced Slope
    typeJournal Paper
    journal volume19
    journal issue5
    journal titleInternational Journal of Geomechanics
    identifier doi10.1061/(ASCE)GM.1943-5622.0001394
    page06019008
    treeInternational Journal of Geomechanics:;2019:;Volume ( 019 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian