    Proposal to Improve the DSM Design of Cold-Formed Steel Angle Columns: Need, Background, Quality Assessment, and Illustration

    Source: Journal of Structural Engineering:;2019:;Volume ( 145 ):;issue: 008
    Author:
    Pedro Borges Dinis
    ,
    Dinar Camotim
    DOI: 10.1061/(ASCE)ST.1943-541X.0002342
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents a proposal for the codification of an efficient design approach based on the direct strength method (DSM) for cold-formed steel equal-leg angle columns with short-to-intermediate lengths, i.e., those buckling in flexural-torsional modes. Initially, the available experimental failure load data consisting of fixed-ended and pin-ended (cylindrical hinges) columns with several geometries (cross-section dimensions and lengths) and tested by various researchers are collected. These are used to show that the currently codified DSM design provisions are not able to handle adequately short-to-intermediate angle columns and that a specific DSM-based design approach is needed to estimate the failure loads of such columns. Then, the paper presents a brief overview of the structural reasoning behind the proposed DSM-based design approach. Next, the quality (accuracy and reliability) of the failure load estimates obtained with this design approach is assessed through the comparison with the aforementioned experimental failure load data and also a fairly large number of numerical failure loads previously obtained by the authors. This merit assessment includes the determination of the load-resistance factor design (LRFD) resistance factors concerning the failure-to-predicted load ratios. It is shown that the value recommended for compression members by the North American specification, ϕc=0.85, can also be adopted for short-to-intermediate angle columns designed with this DSM-based approach. Finally, the paper presents and discusses a few numerical examples that illustrate the application of the proposed design approach and provide evidence of its user-friendliness and advantages/benefits when compared with the currently codified one.
    • Download: (739.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Proposal to Improve the DSM Design of Cold-Formed Steel Angle Columns: Need, Background, Quality Assessment, and Illustration

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259594
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorPedro Borges Dinis
    contributor authorDinar Camotim
    date accessioned2019-09-18T10:37:54Z
    date available2019-09-18T10:37:54Z
    date issued2019
    identifier other%28ASCE%29ST.1943-541X.0002342.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259594
    description abstractThis paper presents a proposal for the codification of an efficient design approach based on the direct strength method (DSM) for cold-formed steel equal-leg angle columns with short-to-intermediate lengths, i.e., those buckling in flexural-torsional modes. Initially, the available experimental failure load data consisting of fixed-ended and pin-ended (cylindrical hinges) columns with several geometries (cross-section dimensions and lengths) and tested by various researchers are collected. These are used to show that the currently codified DSM design provisions are not able to handle adequately short-to-intermediate angle columns and that a specific DSM-based design approach is needed to estimate the failure loads of such columns. Then, the paper presents a brief overview of the structural reasoning behind the proposed DSM-based design approach. Next, the quality (accuracy and reliability) of the failure load estimates obtained with this design approach is assessed through the comparison with the aforementioned experimental failure load data and also a fairly large number of numerical failure loads previously obtained by the authors. This merit assessment includes the determination of the load-resistance factor design (LRFD) resistance factors concerning the failure-to-predicted load ratios. It is shown that the value recommended for compression members by the North American specification, ϕc=0.85, can also be adopted for short-to-intermediate angle columns designed with this DSM-based approach. Finally, the paper presents and discusses a few numerical examples that illustrate the application of the proposed design approach and provide evidence of its user-friendliness and advantages/benefits when compared with the currently codified one.
    publisherAmerican Society of Civil Engineers
    titleProposal to Improve the DSM Design of Cold-Formed Steel Angle Columns: Need, Background, Quality Assessment, and Illustration
    typeJournal Paper
    journal volume145
    journal issue8
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002342
    page04019071
    treeJournal of Structural Engineering:;2019:;Volume ( 145 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian