    Condition Assessment and Strengthening of Aged Structures: Perspectives Based on a Critical Case Study

    Source: Practice Periodical on Structural Design and Construction:;2019:;Volume ( 024 ):;issue: 003
    Author:
    T. Mukhopadhyay
    ,
    S. Naskar
    ,
    S. Dey
    ,
    A. Chakrabarti
    DOI: 10.1061/(ASCE)SC.1943-5576.0000431
    Publisher: American Society of Civil Engineers
    Abstract: This article presents a concise overview on condition monitoring and retrofitting/strengthening of structures, including a practical case study of strengthening for an existing historical building. Condition assessment of an existing structure is required mainly to check serviceability and safety requirements of the structure after short-term events, such as earthquakes or long-term degradation of the structure with time. It is carried out to assess the ability of a structure to perform its intended operations under changed loading conditions with time or modification in its structural system as per newly imposed requirements. The condition assessment and strengthening may also be required for the integrated extension of an existing structure. After assessing the condition of the structure, either it is retrofitted (or strengthened) or it is demolished according to the severity of the damage. In this article, such a critical condition assessment for an existing historical masonry building is presented, and appropriate strengthening schemes are suggested by following two separate measures (concrete jacketing and fiber-reinforced polymer strengthening). Subsequently, the relative advantages and disadvantages of the strengthening measures are discussed from a practical engineering perspective. The aim of this article is not to propose any new method for condition assessment and strengthening of structures; rather, we take a systematic approach to demonstrate our experience. Critical case studies on condition assessment and strengthening of historical buildings with adequate technical insights are very scarce in scientific literature. This article would serve as a valuable reference for practicing engineers and the concerned scientific community.
    • Download: (3.036Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Condition Assessment and Strengthening of Aged Structures: Perspectives Based on a Critical Case Study

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259558
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorT. Mukhopadhyay
    contributor authorS. Naskar
    contributor authorS. Dey
    contributor authorA. Chakrabarti
    date accessioned2019-09-18T10:37:42Z
    date available2019-09-18T10:37:42Z
    date issued2019
    identifier other%28ASCE%29SC.1943-5576.0000431.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259558
    description abstractThis article presents a concise overview on condition monitoring and retrofitting/strengthening of structures, including a practical case study of strengthening for an existing historical building. Condition assessment of an existing structure is required mainly to check serviceability and safety requirements of the structure after short-term events, such as earthquakes or long-term degradation of the structure with time. It is carried out to assess the ability of a structure to perform its intended operations under changed loading conditions with time or modification in its structural system as per newly imposed requirements. The condition assessment and strengthening may also be required for the integrated extension of an existing structure. After assessing the condition of the structure, either it is retrofitted (or strengthened) or it is demolished according to the severity of the damage. In this article, such a critical condition assessment for an existing historical masonry building is presented, and appropriate strengthening schemes are suggested by following two separate measures (concrete jacketing and fiber-reinforced polymer strengthening). Subsequently, the relative advantages and disadvantages of the strengthening measures are discussed from a practical engineering perspective. The aim of this article is not to propose any new method for condition assessment and strengthening of structures; rather, we take a systematic approach to demonstrate our experience. Critical case studies on condition assessment and strengthening of historical buildings with adequate technical insights are very scarce in scientific literature. This article would serve as a valuable reference for practicing engineers and the concerned scientific community.
    publisherAmerican Society of Civil Engineers
    titleCondition Assessment and Strengthening of Aged Structures: Perspectives Based on a Critical Case Study
    typeJournal Paper
    journal volume24
    journal issue3
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)SC.1943-5576.0000431
    page05019003
    treePractice Periodical on Structural Design and Construction:;2019:;Volume ( 024 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian