    Design, Construction, and Operation of a Monitored District Heating Pipeline System

    Source: Journal of Pipeline Systems Engineering and Practice:;2019:;Volume ( 010 ):;issue: 003
    Author:
    Felipe A. Villalobos
    ,
    Stefan Hay
    ,
    Ingo Weidlich
    ,
    Ingo Wolf
    DOI: 10.1061/(ASCE)PS.1949-1204.0000388
    Publisher: American Society of Civil Engineers
    Abstract: The need for understanding the performance of district heating pipeline systems has led to the development of a monitoring program. This program includes the design of the connection of an instrumented section of piping within an in-use district heating network. The design complies with the current European district heating recommendations and standards. Monitoring consists of the measurement of earth pressures against the pipes, axial pipe displacements, and temperature of the fluid and soil around the pipes. There are different conditions being tested such as thickness of insulation materials, temperature ranges, and bedding soil type. In particular, there is interest in testing the corner positions. Details of the piping and instrumentation arrangements as well as soil geotechnical characteristics are presented. It was found that when the fluid temperature increased from ambient conditions up to 90°C, pipes were moving all along their length. Moreover, after a fluid temperature drop from 90°C to 20°C over 20 days and subsequent increase to 90°C again, pipe axial displacements did not return to the same values as before.
    • Download: (2.429Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design, Construction, and Operation of a Monitored District Heating Pipeline System

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4259544
    Collections
    • Journal of Pipeline Systems Engineering and Practice

    Show full item record

    contributor authorFelipe A. Villalobos
    contributor authorStefan Hay
    contributor authorIngo Weidlich
    contributor authorIngo Wolf
    date accessioned2019-09-18T10:37:38Z
    date available2019-09-18T10:37:38Z
    date issued2019
    identifier other%28ASCE%29PS.1949-1204.0000388.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259544
    description abstractThe need for understanding the performance of district heating pipeline systems has led to the development of a monitoring program. This program includes the design of the connection of an instrumented section of piping within an in-use district heating network. The design complies with the current European district heating recommendations and standards. Monitoring consists of the measurement of earth pressures against the pipes, axial pipe displacements, and temperature of the fluid and soil around the pipes. There are different conditions being tested such as thickness of insulation materials, temperature ranges, and bedding soil type. In particular, there is interest in testing the corner positions. Details of the piping and instrumentation arrangements as well as soil geotechnical characteristics are presented. It was found that when the fluid temperature increased from ambient conditions up to 90°C, pipes were moving all along their length. Moreover, after a fluid temperature drop from 90°C to 20°C over 20 days and subsequent increase to 90°C again, pipe axial displacements did not return to the same values as before.
    publisherAmerican Society of Civil Engineers
    titleDesign, Construction, and Operation of a Monitored District Heating Pipeline System
    typeJournal Paper
    journal volume10
    journal issue3
    journal titleJournal of Pipeline Systems Engineering and Practice
    identifier doi10.1061/(ASCE)PS.1949-1204.0000388
    page04019018
    treeJournal of Pipeline Systems Engineering and Practice:;2019:;Volume ( 010 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian