Show simple item record

contributor authorYang, Che-Hao
contributor authorLi, Wei
contributor authorChen, Roland K.
date accessioned2019-09-18T09:07:01Z
date available2019-09-18T09:07:01Z
date copyright4/2/2019 12:00:00 AM
date issued2019
identifier issn1087-1357
identifier othermanu_141_5_054502
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4259049
description abstractElectrosurgical tissue joining is an effective way to create hemostasis, especially in surgical procedures performed in the minimally invasive manner. The quality of tissue joints and potential thermal damages to the surroundings are the two main concerns when using electrosurgical tissue joining tools. A more robust method for quality control is still needed. The goal of this study is to characterize the joining process using dynamic impedance and energy efficiency. Three joining times (4, 6, and 8 s) and three compression levels (80%, 90%, and 95%) were used to join porcine arterial tissues while the process parameters including voltage, current, and impedance were monitored. Tensile tests were performed to evaluate the quality of tissue joints. A new index, the strength-energy coefficient (mmHg/J), which is defined as the tensile strength divided by the consumed energy, is introduced to evaluate the energy efficiency of the joining process. Strength-energy coefficient offers a new way to estimate the required joining time to achieve sufficient joining strength while minimizing the energy consumption to reduce thermal damages. The 95% compression level has the highest strength-energy coefficient for 4- and 6-s joining times. This indicates that the 95% compression level has higher energy efficiency and can form a good tissue joint with less energy and time in comparison with those required by a lower compression level. The progression of the tissue joining process was characterized by the real-time impedance measurement, which can be used as a tool for quality control.
publisherAmerican Society of Mechanical Engineers (ASME)
titleCharacterization of the Electrosurgical Tissue Joining Process Using Dynamic Impedance and Energy Efficiency
typeJournal Paper
journal volume141
journal issue5
journal titleJournal of Manufacturing Science and Engineering
identifier doi10.1115/1.4043267
journal fristpage54502
journal lastpage054502-5
treeJournal of Manufacturing Science and Engineering:;2019:;volume( 141 ):;issue: 005
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record