Digital Image Processing Techniques for Evaluating Façade Flatness in Historical BuildingsSource: Journal of Architectural Engineering:;2019:;Volume (025):;issue:002Author:Emanuele Calabrò
DOI: doi:10.1061/(ASCE)AE.1943-5568.0000359Publisher: American Society of Civil Engineers
Abstract: This study reports a rapid method of analysis for evaluating the flatness of the façades of historical buildings. This method applies topographic, digital photogrammetric, and image processing techniques to measurements acquired by a semimetric camera in order to provide a planar metrified and rectified image. The use of this technique allows for the virtual control of alterations of a building’s geometrical and physical surface characteristics that have been induced by environmental decay and have possibly resulted in some deviation from flatness. We used the semimetric cameras Rolleiflex 3003 and Rolleiflex 6006 and a two-dimensional (2D) algorithm to verify the flatness of the main façade of a monument, the Zisa Palace in Palermo (Italy). The results of this study, which highlighted some deviations in the left edge of the façade with respect to the points of support, were obtained with an estimated 10−3 accuracy. Accurate statistical analysis applied to the measurements showed that the façade of this historical building is not a flat surface, suggesting that decay processes have occurred. Hence, this method can be used to easily demonstrate nonflatness of a façade of a historical building and to highlight structural failures in areas of the façade.
|
Collections
Show full item record
| contributor author | Emanuele Calabrò | |
| date accessioned | 2019-06-08T07:25:56Z | |
| date available | 2019-06-08T07:25:56Z | |
| date issued | 2019 | |
| identifier other | %28ASCE%29AE.1943-5568.0000359.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4257336 | |
| description abstract | This study reports a rapid method of analysis for evaluating the flatness of the façades of historical buildings. This method applies topographic, digital photogrammetric, and image processing techniques to measurements acquired by a semimetric camera in order to provide a planar metrified and rectified image. The use of this technique allows for the virtual control of alterations of a building’s geometrical and physical surface characteristics that have been induced by environmental decay and have possibly resulted in some deviation from flatness. We used the semimetric cameras Rolleiflex 3003 and Rolleiflex 6006 and a two-dimensional (2D) algorithm to verify the flatness of the main façade of a monument, the Zisa Palace in Palermo (Italy). The results of this study, which highlighted some deviations in the left edge of the façade with respect to the points of support, were obtained with an estimated 10−3 accuracy. Accurate statistical analysis applied to the measurements showed that the façade of this historical building is not a flat surface, suggesting that decay processes have occurred. Hence, this method can be used to easily demonstrate nonflatness of a façade of a historical building and to highlight structural failures in areas of the façade. | |
| publisher | American Society of Civil Engineers | |
| title | Digital Image Processing Techniques for Evaluating Façade Flatness in Historical Buildings | |
| type | Journal Article | |
| journal volume | 25 | |
| journal issue | 2 | |
| journal title | Journal of Architectural Engineering | |
| identifier doi | doi:10.1061/(ASCE)AE.1943-5568.0000359 | |
| page | 05019005 | |
| tree | Journal of Architectural Engineering:;2019:;Volume (025):;issue:002 | |
| contenttype | Fulltext |