Show simple item record

contributor authorLyu, Yuan-wei
contributor authorZhang, Jing-zhou
contributor authorLiu, Xi-cheng
contributor authorShan, Yong
date accessioned2019-03-17T11:18:29Z
date available2019-03-17T11:18:29Z
date copyright1/14/2019 12:00:00 AM
date issued2019
identifier issn0022-1481
identifier otherht_141_03_032201.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256882
description abstractImpinging heat transferred by a pulsed jet induced by a six-chevron nozzle on a semicylindrical concave surface is investigated by varying jet Reynolds numbers (5000 ≤ Re ≤ 20,000), operational frequencies (0 Hz ≤ f ≤ 25 Hz), and dimensionless nozzle-to-surface distances (1 ≤ H/d ≤ 8) while fixing the duty cycle as DC = 0.5. The semicylindrical concave surface has a cylinder diameter-to-nozzle diameter ratio (D/d) of 10. The results show that the nozzle-to-surface distance has a significant impact on the impingement heat transfer of the pulsed chevron jet. An optimal nozzle-to-surface distance for achieving the maximum stagnation Nusselt number appears at H/d  =  6. In the wall jet zone, the averaged Nusselt number is the largest at H/d = 2 and the smallest at H/d = 8. In comparison with the chevron steady jet impingement, the effect of nozzle-to-surface distance on the convective heat transfer becomes less notable for the pulsed chevron jet impingement. The stagnation Nusselt number under the pulsed chevron jet impingement is mostly less than that under the chevron steady jet impingement. However, at H/d = 8, the pulsed chevron jet is more effective than the steady jet. This study confirmed that the pulsed chevron jet produced higher azimuthally averaged Nusselt numbers than the steady chevron jet in the wall jet flow zone at large nozzle-to-surface distances. The stagnation Nusselt numbers by the pulsed chevron jet impingement have a maximum reduction of 21.0% (f = 20 Hz, H/d = 4, and Re = 2000) compared with that of the steady chevron jet impingement. Also, the pulsed chevron jet impingement heat transfer on a concave surface is less effective compared to a flat surface. The stagnation Nusselt numbers on the semicylindrical concave surface have a maximum reduction of about 37.7% (f = 20 Hz, H/d = 8, and Re = 5000) compared with that on the flat surface.
publisherThe American Society of Mechanical Engineers (ASME)
titleExperimental Investigation of Impinging Heat Transfer of the Pulsed Chevron Jet on a Semicylindrical Concave Plate
typeJournal Paper
journal volume141
journal issue3
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4042159
journal fristpage32201
journal lastpage032201-15
treeJournal of Heat Transfer:;2019:;volume( 141 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record