Show simple item record

contributor authorBarone, William R.
contributor authorKnight, Katrina M.
contributor authorMoalli, Pamela A.
contributor authorAbramowitch, Steven D.
date accessioned2019-03-17T10:58:55Z
date available2019-03-17T10:58:55Z
date copyright11/29/2018 12:00:00 AM
date issued2019
identifier issn0148-0731
identifier otherbio_141_02_021001.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256482
description abstractSynthetic mesh for pelvic organ prolapse (POP) repair is associated with high complication rates. While current devices incorporate large pores (>1 mm), recent studies have shown that uniaxial loading of mesh reduces pore size, raising the risk for complications. However, it is difficult to translate uniaxial results to transvaginal meshes, as in vivo loading is multidirectional. Thus, the aim of this study was to (1) experimentally characterize deformation of pore diameters in a transvaginal mesh in response to clinically relevant multidirectional loading and (2) develop a computational model to simulate mesh behavior in response to in vivo loading conditions. Tension (2.5 N) was applied to each of mesh arm to simulate surgical implantation. Two loading conditions were assessed where the angle of the applied tension was altered and image analysis was used to quantify changes in pore dimensions. A computational model was developed and used to simulate pore behavior in response to these same loading conditions and the results were compared to experimental findings. For both conditions, between 26.4% and 56.6% of all pores were found to have diameters <1 mm. Significant reductions in pore diameter were noted in the inferior arms and between the two superior arms. The computational model identified the same regions, though the model generally underestimated pore deformation. This study demonstrates that multiaxial loading applied clinically has the potential to locally reduce porosity in transvaginal mesh, increasing the risk for complications. Computational simulations show potential of predicting this behavior for more complex loading conditions.
publisherThe American Society of Mechanical Engineers (ASME)
titleDeformation of Transvaginal Mesh in Response to Multiaxial Loading
typeJournal Paper
journal volume141
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4041743
journal fristpage21001
journal lastpage021001-8
treeJournal of Biomechanical Engineering:;2019:;volume( 141 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record