Show simple item record

contributor authorCaulk, Alexander W.
contributor authorHumphrey, Jay D.
contributor authorMurtada, Sae-Il
date accessioned2019-03-17T09:42:43Z
date available2019-03-17T09:42:43Z
date copyright1/25/2019 12:00:00 AM
date issued2019
identifier issn0148-0731
identifier otherbio_141_03_031008.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255632
description abstractVascular smooth muscle cells (VSMCs) can regulate arterial mechanics via contractile activity in response to changing mechanical and chemical signals. Contractility is traditionally evaluated via uniaxial isometric testing of isolated rings despite the in vivo environment being very different. Most blood vessels maintain a locally preferred value of in vivo axial stretch while subjected to changes in distending pressure, but both of these phenomena are obscured in uniaxial isometric testing. Few studies have rigorously analyzed the role of in vivo loading conditions in smooth muscle function. Thus, we evaluated effects of uniaxial versus biaxial deformations on smooth muscle contractility by stimulating two regions of the mouse aorta with different vasoconstrictors using one of three testing protocols: (i) uniaxial isometric testing, (ii) biaxial isometric testing, and (iii) axially isometric plus isobaric testing. Comparison of methods (i) and (ii) revealed increased sensitivity and contractile capacity to potassium chloride and phenylephrine (PE) with biaxial isometric testing, and comparison of methods (ii) and (iii) revealed a further increase in contractile capacity with isometric plus isobaric testing. Importantly, regional differences in estimated in vivo axial stretch suggest locally distinct optimal biaxial configurations for achieving maximal smooth muscle contraction, which can only be revealed with biaxial testing. Such differences highlight the importance of considering in vivo loading and geometric configurations when evaluating smooth muscle function. Given the physiologic relevance of axial extension and luminal pressurization, we submit that, when possible, axially isometric plus isobaric testing should be employed to evaluate vascular smooth muscle contractile function.
publisherThe American Society of Mechanical Engineers (ASME)
titleFundamental Roles of Axial Stretch in Isometric and Isobaric Evaluations of Vascular Contractility
typeJournal Paper
journal volume141
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4042171
journal fristpage31008
journal lastpage031008-10
treeJournal of Biomechanical Engineering:;2019:;volume( 141 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record