    Archive

    Prediction of Freezing Temperature inside Concrete Crossties at the Rail Seat Area

    Source: Journal of Materials in Civil Engineering:;2019:;Volume ( 031 ):;issue: 001
    Author:
    Daniel I. Castaneda; Kyle A. Riding; David A. Lange
    DOI: 10.1061/(ASCE)MT.1943-5533.0002528
    Publisher: American Society of Civil Engineers
    Abstract: Air-entrained high performance concrete (HPC) crossties or ties (alternatively called sleepers outside of North America) have been observed to suffer structural and material degradation at the rail seat area (RSA), including freeze-thaw damage. The manifestation of any damage at the RSA is hazardous because future high-speed railroad lines utilizing HPC crossties will be installed in regions across the United States with extensive freeze-thaw temperature cycling. To better understand the extent of cyclic freezing temperatures at the RSA, an environmental study was undertaken to measure the internal temperature at various locations of instrumented HPC crossties that were installed in a track for 1 year. The experimentally measured internal temperature values are compared against the results of a pair of models (a solar radiation model and a one-dimensional, multilayered heat transfer model) that utilize only public weather data as model inputs. The pair of models is found to satisfactorily predict the freezing internal temperatures of concrete crossties, specifically during winter months. The validation of this temperature modeling expands the HPC crosstie practitioner’s set of tools necessary to better understand environmental design criteria of this critical piece of infrastructure with regard to freeze-thaw damage.
    • Download: (2.637Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Prediction of Freezing Temperature inside Concrete Crossties at the Rail Seat Area

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4255266
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorDaniel I. Castaneda; Kyle A. Riding; David A. Lange
    date accessioned2019-03-10T12:17:26Z
    date available2019-03-10T12:17:26Z
    date issued2019
    identifier other%28ASCE%29MT.1943-5533.0002528.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255266
    description abstractAir-entrained high performance concrete (HPC) crossties or ties (alternatively called sleepers outside of North America) have been observed to suffer structural and material degradation at the rail seat area (RSA), including freeze-thaw damage. The manifestation of any damage at the RSA is hazardous because future high-speed railroad lines utilizing HPC crossties will be installed in regions across the United States with extensive freeze-thaw temperature cycling. To better understand the extent of cyclic freezing temperatures at the RSA, an environmental study was undertaken to measure the internal temperature at various locations of instrumented HPC crossties that were installed in a track for 1 year. The experimentally measured internal temperature values are compared against the results of a pair of models (a solar radiation model and a one-dimensional, multilayered heat transfer model) that utilize only public weather data as model inputs. The pair of models is found to satisfactorily predict the freezing internal temperatures of concrete crossties, specifically during winter months. The validation of this temperature modeling expands the HPC crosstie practitioner’s set of tools necessary to better understand environmental design criteria of this critical piece of infrastructure with regard to freeze-thaw damage.
    publisherAmerican Society of Civil Engineers
    titlePrediction of Freezing Temperature inside Concrete Crossties at the Rail Seat Area
    typeJournal Paper
    journal volume31
    journal issue1
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0002528
    page04018358
    treeJournal of Materials in Civil Engineering:;2019:;Volume ( 031 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian