Show simple item record

contributor authorHussein, Amira I.
contributor authorLouzeiro, Daniel T.
contributor authorUnnikrishnan, Ginu U.
contributor authorMorgan, Elise F.
date accessioned2019-02-28T11:10:53Z
date available2019-02-28T11:10:53Z
date copyright1/12/2018 12:00:00 AM
date issued2018
identifier issn0148-0731
identifier otherbio_140_02_021004.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253540
description abstractVertebral fractures are common in the elderly, but efforts to reduce their incidence have been hampered by incomplete understanding of the failure processes that are involved. This study's goal was to elucidate failure processes in the lumbar vertebra and to assess the accuracy of quantitative computed tomography (QCT)-based finite element (FE) simulations of these processes. Following QCT scanning, spine segments (n = 27) consisting of L1 with adjacent intervertebral disks and neighboring endplates of T12 and L2 were compressed axially in a stepwise manner. A microcomputed tomography scan was performed at each loading step. The resulting time-lapse series of images was analyzed using digital volume correlation (DVC) to quantify deformations throughout the vertebral body. While some diversity among vertebrae was observed on how these deformations progressed, common features were large strains that developed progressively in the superior third and, concomitantly, in the midtransverse plane, in a manner that was associated with spatial variations in microstructural parameters such as connectivity density. Results of FE simulations corresponded qualitatively to the measured failure patterns when boundary conditions were derived from DVC displacements at the endplate. However, quantitative correspondence was often poor, particularly when boundary conditions were simplified to uniform compressive loading. These findings suggest that variations in trabecular microstructure are one cause of the differences in failure patterns among vertebrae and that both the lack of incorporation of these variations into QCT-based FE models and the oversimplification of boundary conditions limit the accuracy of these models in simulating vertebral failure.
publisherThe American Society of Mechanical Engineers (ASME)
titleDifferences in Trabecular Microarchitecture and Simplified Boundary Conditions Limit the Accuracy of Quantitative Computed Tomography-Based Finite Element Models of Vertebral Failure
typeJournal Paper
journal volume140
journal issue2
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4038609
journal fristpage21004
journal lastpage021004-11
treeJournal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record