    Untitled

    Source: Journal of Composites for Construction:;2018:;Volume ( 022 ):;issue: 003
    Author:
    Zou Xingxing;Feng Peng;Wang Jingquan
    DOI: 10.1061/(ASCE)CC.1943-5614.0000845
    Publisher: American Society of Civil Engineers
    Abstract: This study investigated the behavior of bolted shear connections for fiber-reinforced polymer (FRP)–concrete hybrid beams. Fourteen push-out tests were conducted with varying parameters of bolt strength, bolt diameter (dbolt), bolt-embedding length in concrete (hbolt), FRP shear strength (SFRP), and the use of ultra-high performance concrete (UHPC). Tests showed that a larger hbolt leads to smaller slip but has only a slight effect on capacity; specimens with a larger dbolt have greater capacity and smaller slip. Specimens with ordinary-strength bolts (OSBs) failed at bolt shank shear, whereas specimens with high-strength bolts (HSB) failed at FRP flange shear-out associated with a significant improvement in capacity compared with those with OSBs. The use of UHPC substantially reduced slip, but did not improve bolt capacity because the two failure modes do not occur in concrete. The prediction equations for capacity associated with these two failure modes were derived by modifying the existing equations. A salient finding in the load-slip curves of HSB specimens was three loading stages with different slopes: compacting, hardening, and softening. This was different from observations in previous studies on head studs in steel-concrete composite beams and FRP bolts/dowels in FRP-concrete hybrid beams. The load-slip curves of specimens with HSB were fitted by a trilinear model to facilitate design and analysis. Finally, design recommendations for bolted connections were formulated after parametric analysis.
    • Download: (1.180Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4250485
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorZou Xingxing;Feng Peng;Wang Jingquan
    date accessioned2019-02-26T07:57:06Z
    date available2019-02-26T07:57:06Z
    date issued2018
    identifier other%28ASCE%29CC.1943-5614.0000845.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250485
    description abstractThis study investigated the behavior of bolted shear connections for fiber-reinforced polymer (FRP)–concrete hybrid beams. Fourteen push-out tests were conducted with varying parameters of bolt strength, bolt diameter (dbolt), bolt-embedding length in concrete (hbolt), FRP shear strength (SFRP), and the use of ultra-high performance concrete (UHPC). Tests showed that a larger hbolt leads to smaller slip but has only a slight effect on capacity; specimens with a larger dbolt have greater capacity and smaller slip. Specimens with ordinary-strength bolts (OSBs) failed at bolt shank shear, whereas specimens with high-strength bolts (HSB) failed at FRP flange shear-out associated with a significant improvement in capacity compared with those with OSBs. The use of UHPC substantially reduced slip, but did not improve bolt capacity because the two failure modes do not occur in concrete. The prediction equations for capacity associated with these two failure modes were derived by modifying the existing equations. A salient finding in the load-slip curves of HSB specimens was three loading stages with different slopes: compacting, hardening, and softening. This was different from observations in previous studies on head studs in steel-concrete composite beams and FRP bolts/dowels in FRP-concrete hybrid beams. The load-slip curves of specimens with HSB were fitted by a trilinear model to facilitate design and analysis. Finally, design recommendations for bolted connections were formulated after parametric analysis.
    publisherAmerican Society of Civil Engineers
    typeJournal Paper
    journal volume22
    journal issue3
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000845
    page4018012
    treeJournal of Composites for Construction:;2018:;Volume ( 022 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian