    Modeling Corrosion in Suspension Bridge Main Cables. I: Annual Corrosion Rate

    Source: Journal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    Author:
    Karanci Efe;Betti Raimondo
    DOI: 10.1061/(ASCE)BE.1943-5592.0001233
    Publisher: American Society of Civil Engineers
    Abstract: Accurately determining the current state of the main cables of a suspension bridge is critical to assessing the safety of the bridge. These cables are composed of thousands of individual bridge wires, each of which deteriorates over time at a different rate. Current inspection methods provide an incomplete picture of the condition across the cable section, so cable strength estimation methods that rely on this inspection data involve considerable uncertainty. Furthermore, there is no method for estimating the continuing decline in cable strength following an inspection due to ongoing corrosion. This paper lays the groundwork for a time-dependent corrosion-rate model for bridge wires by using monitored environmental parameters from the cable interior. To establish this model, a methodology to estimate the annual corrosion rate as a function of environmental variables was proposed. First, experimental data on the corrosion rate of carbon steel from previous studies were analyzed using machine learning methods. Temperature, relative humidity, pH, and Cl− concentration were determined to be the most relevant variables for predicting the corrosion rate. Next, cyclic corrosion tests were performed by subjecting bridge wires to various levels of these environmental variables, and the resulting data were used to augment the experimental data set from previous studies. Finally, a corrosion-rate model that predicts the annual corrosion rate of bridge wires was developed using the augmented data set.
    • Download: (2.212Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Modeling Corrosion in Suspension Bridge Main Cables. I: Annual Corrosion Rate

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4250241
    Collections
    • Journal of Bridge Engineering

    Show full item record

    contributor authorKaranci Efe;Betti Raimondo
    date accessioned2019-02-26T07:54:51Z
    date available2019-02-26T07:54:51Z
    date issued2018
    identifier other%28ASCE%29BE.1943-5592.0001233.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4250241
    description abstractAccurately determining the current state of the main cables of a suspension bridge is critical to assessing the safety of the bridge. These cables are composed of thousands of individual bridge wires, each of which deteriorates over time at a different rate. Current inspection methods provide an incomplete picture of the condition across the cable section, so cable strength estimation methods that rely on this inspection data involve considerable uncertainty. Furthermore, there is no method for estimating the continuing decline in cable strength following an inspection due to ongoing corrosion. This paper lays the groundwork for a time-dependent corrosion-rate model for bridge wires by using monitored environmental parameters from the cable interior. To establish this model, a methodology to estimate the annual corrosion rate as a function of environmental variables was proposed. First, experimental data on the corrosion rate of carbon steel from previous studies were analyzed using machine learning methods. Temperature, relative humidity, pH, and Cl− concentration were determined to be the most relevant variables for predicting the corrosion rate. Next, cyclic corrosion tests were performed by subjecting bridge wires to various levels of these environmental variables, and the resulting data were used to augment the experimental data set from previous studies. Finally, a corrosion-rate model that predicts the annual corrosion rate of bridge wires was developed using the augmented data set.
    publisherAmerican Society of Civil Engineers
    titleModeling Corrosion in Suspension Bridge Main Cables. I: Annual Corrosion Rate
    typeJournal Paper
    journal volume23
    journal issue6
    journal titleJournal of Bridge Engineering
    identifier doi10.1061/(ASCE)BE.1943-5592.0001233
    page4018025
    treeJournal of Bridge Engineering:;2018:;Volume ( 023 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian